Climate & Heating (WHO = 4)¶
The MyHOME integration provides full control for heating, cooling, central thermoregulation units, and zone thermostats operating on OpenWebNet WHO = 4.
In v2, setup and management are 100% UI-first: climate zones and central units are automatically discovered over the SCS bus without manual YAML configuration files.
๐ Auto-Discovery¶
When your gateway connects to Home Assistant:
- Dynamic Bus Discovery: The integration listens to OpenWebNet
WHO = 4temperature and setpoint messages broadcast on the SCS bus. - Entity Creation: Each active thermoregulation zone (
WHERE = 1..99or central unit#0) is registered as a Home Assistantclimateentity linked to your gateway. - UI Customization: You can rename the zone, assign it to an Area (e.g. Master Bedroom, Living Room), and adjust temperature step increments directly in the Home Assistant UI.
๐๏ธ Supported Plant Architectures¶
MyHOME installations typically deploy one of three climate topologies, all natively supported by the v2 discovery engine:
1. 99-Zone Central Unit Architecture (BTicino 3550 / #0)¶
- Hardware: Central thermoregulation unit (BTicino
3550, MyHOME_Screen 10, or MyHOME_Screen 3.5) operating at master addressWHERE = #0. - Subordinate Zones: Individual room zones (
WHERE = 1..99) with local probes (L4693,H4693,LN4693, etc.) andF430/2orF430/4flush/DIN actuators. - Operation: The integration discovers the central unit (
#0) as the masterclimateentity and each individual zone (1..99) as a controllableclimatedevice. Subordinate zone setpoint and mode commands use the central-unit-routed#Zaddress format (*#4*#Z*#14*TTTT*M##,*4*311*#Z##,*4*303*#Z##). - Central unit modes:
offsends*4*303*#0##;autoasks the central unit for its program andheat/coolfor the season (OWNd'sset_central_modebuilds the frames). With OWNd 2.0.0b13autois*4*311*#0##, which a live3550behind an F461 did not act on (ACKed and forwarded, central unit still OFF 8 s later, 2026-11-12); the OWNd change proposed with this (set_central_mode('#0', 'auto')-> the published last-weekly-program command*4*3100*#0##, WHO 4 PDF ยง1.6.8) takes effect once the pin moves to a release that carries it; the3550answered that frame within 0.15 s with*4*2101*#0##(weekly program 1, conditioning).off/autoare shown at once and then follow the central unit's report (after a program restore the entity shows the reported season andprogram);heat/coolwait for the central unit's answer (the mode it is in, or nothing when the season does not change; live F461 + F455, 2026-11-08). - Startup & Reconnect Status Burst (
*#4*#0##): On startup (including on SCS-only gateways such asMH200NandF454), the central unit entity queries*#4*#0##. The3550responds with its operating mode frame (e.g.*4*1101*#0##for Heating Weekly Program 1,*4*110#0200*#0##for Manual 20.0 ยฐC, or*4*102*#0##for Antifreeze/Protection) followed by diagnostic status frames (WHAT 20..24, 30, 31), exposed on the#0entity as state attributes:remote_control:"enabled"(*4*21*#0##) or"disabled"(*4*20*#0##, raises the self-clearingcentral_remote_control_disabledrepair issue).at_least_one_probe_off:truewhen*4*22*#0##is reported in the current burst.at_least_one_probe_antifreeze:truewhen*4*23*#0##is reported in the current burst.at_least_one_probe_manual:truewhen*4*24*#0##is reported in the current burst.failure_detected:truewhen*4*30*#0##(Failure discovered in a zone) is reported in the current burst.battery_fault:truewhen*4*31*#0##(Central unit battery KO) is reported in the current burst (raises the self-clearingcentral_battery_faultrepair issue).
- Remote Control (Telegestione) Requirement: On a physical BTicino
3550, Remote Control (Telegestione) must be set to Enabled (Abilitata) in the3550menu (*4*21*#0##) for the central unit to accept remote commands over the bus. When*4*20*#0##is active, the gateway still replies*#*1##(ACK), but the3550ignores remote mode and setpoint writes. - Subordinate Zone Control Patterns (
AutovsManual):
| Control Pattern | Central Unit (#0) Mode |
Subordinate Zone (1..99) Mode |
How Setpoint & Schedule Changes Work |
|---|---|---|---|
1. 3550 as Schedule Master + HA Temporary Overrides |
auto (Weekly Program 1..3 or Scenario 1..16) |
auto (*4*111*#Z## / *4*211*#Z##) |
Calling climate.set_temperature on a zone writes *#4*#Z*#14*TTTT*3##, placing that zone into manual setpoint override (*4*110*#Z##, hvac_mode: heat/cool, #0 reports at_least_one_probe_manual: true). Setting the zone's hvac_mode back to auto sends *4*311*#Z## and returns the zone to the 3550's active weekly schedule. |
| 2. Home Assistant as Full Schedule Master | heat, cool, or auto |
heat / cool (Manual setpoint per room) |
Each zone is driven directly by Home Assistant automations or the HA Schedule integration calling climate.set_temperature (*#4*#Z*#14*TTTT*3##) or climate.set_hvac_mode (heat, cool, off) on each room entity independently. |
2. 4-Zone Central Unit Architecture¶
- Hardware: BTicino
HC4695,L4695, orLN46954-zone master display panel. - Operation: The master panel acts as Zone 1 (or its assigned zone number) while coordinating up to three subordinate zones.
3. Standalone Probes (No Central Unit)¶
- Hardware: Autonomous room thermostats (BTicino
H4691,LN4691,L4692) acting as independent temperature controllers without a master central display. - Operation: Each thermostat is exposed directly as an independent
climateentity with full target setpoint and mode control. - Modes offered: on a plant that also has a central unit, a standalone thermostat does not offer
autoonce the central unit is known (the central unit has no program for it: the live F461 ACKs*4*311*#2##and nothing answers;autoon zone 2 was refused on both gateway entries, 2026-11-12). A zone of the central unit does not offer the off-season mode while the season is reported (heaton zone 4 of a 3550 in conditioning was refused, 2026-11-12). The mode a zone shows is never dropped from the list.
๐ก๏ธ Push-Driven Secondary Probes (WHERE โฅ 100)¶
In plants with secondary temperature sensors (e.g. BTicino 3455 radio probes connected via L4577 radio interfaces), sensor addresses have 3 digits (e.g. WHERE = 105 corresponds to the first secondary probe of Zone 5).
- Push-Driven Telemetry: These battery-powered or radio sensors broadcast their temperature updates periodically on the SCS bus and actively reject direct poll requests.
- v2 Quiet Listening: The v2 climate engine recognizes secondary probe addresses, operates in receive-only mode, and suppresses redundant polling to prevent gateway NACKs.
Tip
Projecting External Temperatures onto the Bus: To publish Home Assistant temperature sensors (e.g. Zigbee room thermometers, weather forecasts, or ESPHome probes) onto an SCS probe address for display on wall screens and thermostats, use the Expose to Bus Guide.
๐๏ธ Supported Features & HVAC Modes¶
MyHOME climate entities support standard Home Assistant climate controls:
- HVAC Modes:
heat: System active in heating mode.cool: System active in cooling / air-conditioning mode.auto: Following scheduled setpoint or central program.off: System frost-protection or thermal shutdown.
- Target Temperature: Adjustable setpoint slider in 0.5 ยฐC increments.
The slider shows the setpoint the thermostat regulates to (dimension 12, knob offset included) whenever the zone has reported it; the commanded setpoint (dimension 14) is only shown until then. On an F461 the two can differ (21.0 commanded, 23.5 in force on a live capture), and the attribute
local_target_temperaturecarries the same value. When the zone leavesoff, the value reported while it was off is taken as the protection setpoint (#383), so the commanded setpoint is shown until the zone reports dimension 12 again; after aset_temperaturecall the next report, dimension 12 or 14, is shown. The value restored after a restart of Home Assistant already carries the savedlocal_offset, so the first dimension 13 report does not add it again. - Current Temperature: Real-time ambient reading reported by the probe.
On single-session or uncaptured SCS-only gateways whose firmware drops the general request
*#4*0##(F450, F459, H4684, MH200, MH201), each local zone asks for its own temperature with*#4*<WHERE>*0##after the startup sweep, so a standalone thermostat is notunknownuntil it next reports (#185). F454, MH202, F460, F461 and MyHomeServer1 drop*#4*0##as well but answer the zone status request*#4*<WHERE>##themselves (the F454 supports up to 4 command sessions and answers in ~1.3 s on both central-unit #629 and standalone #866 plants, the MH202 answers in ~160-250 ms, #866, the F460 and F461 expand it into one request, and the MyHomeServer1 replies from its cache), so their local zones keep that poll. A zone behind an F422 bus interface (WHERE = <zone>#4#<interface>) is never polled unless the OWNd profile setssupports_interface_zone_requests = True(see below), so it shows its restored reading until it reports by itself. After a restart the last reading is shown with the attributecurrent_temperature_restored: trueuntil the zone reports again. - Current Humidity: Ambient relative humidity percentage for zones equipped with humidity sensors (e.g. Living Now thermostats or humidity probes).
- HVAC Action and
actuators: a local zone asks for the state of its actuators (*#4*<WHERE>*20##, one*#4*#0*20##for every local zone on an F461 or a MyHomeServer1) once the startup sweep is over and again after the event session reconnects, sohvac_action(heating/cooling/idle) is known right after start instead of after the first actuator switch. The attributeactuatorslists each actuator asonoroff({"1": "off", "2": "off"}) and stays while the zone is off (every actuatoroff). F453, F453AV, H4684, MH200, MH200N and MH202 drop the request (firmware oracle), so their zones are not asked and wait for the actuators' own frames; the F455 refuses the zone form at once but answers the actuator form*#4*<WHERE>#<N>*20##(live F455 1.0.76), so only its thermo actuator switches ask it; on a shared bus the gateway that serves WHO 4 (delegated secondary or warm standby) decides. Secondary probes (WHERE >= 100) are never asked. Probe-lessF430/2/F430/4relays (such as bathroom towel warmers that only emit Dimension 20 actuator status frames without a temperature probe) do not create phantomclimateentities and can be controlled asswitchentities via Add thermo actuator / towel-warmer switch (WHO 4) (see Switches & Relays). - Zones that have not reported after a start (every gateway): 30 s after the startup sweep, and after its own startup poll, a zone that has not reported its temperature, setpoint and mode (a value restored from before the restart does not count) asks for what is still missing, one read at a time:
*#4*<zone>*0##(only when the temperature is missing),*#4*<zone>*13##(the knob, unless the zone already asked for it),*#4*<zone>*14##,*#4*<zone>*12##and*#4*<zone>#1*20##(not on F453, F453AV, H4684, MH200, MH200N and MH202, which drop the actuator request). A knob read that was sent when the zone was added and brought nothing is repeated once, as the last read. The zones are asked one after another; each read waits for the previous answer and then for the bus to be quiet (no frame for 0.75 s), and a refused or unanswered read (a NACK, a timeout, or an ACK that brought no frame) ends the poll, so a zone without a probe costs one read. A read that collected only another zone's frame is sent once more, unless the zone's own answer arrived in the meantime. This goes by the result, not by a list of gateway models: a zone that got everything from the sweep, from its status request*#4*<WHERE>##or from its thermostat sends nothing, so on a gateway that answers the status request (F454, F460, F461, MH202, MyHomeServer1) the poll normally asks nothing, and a zone that answered neither of its last two status requests (unresponsive_zonerepair) is left alone. Until now only F455 zones were asked this way (#466); on the other gateways whose zones are not sent the status request,temperaturestayed empty after a start until a thermostat published a change (#932 on an MH201). After a restart the saved setpoint is shown at once and is replaced by the zone's own value when it arrives. On a shared bus a passive standby or secondary asks nothing. Run on a physical F455 1.0.76 (#466, #932). On a physical MH201 3.6.43 the reporter of #932 ran the poll in its first form (the MH201 added to the F455's list) and every zone got its setpoint; for F450, F453, F453AV, F459, H4684, MH200 and MH200N the firmware oracle shows each of these reads going out to the bus, and the poll has not yet run on a physical plant; F452 and F458 are not in the oracle. - Zones on an F455 (Basic Gateway): the F455 ACKs
*#4*0##only after about 9 s and sends nothing, so the startup sweep leaves that request out; it ACKs the zone status request*#4*<WHERE>##only after about 9 s and refuses*#4*<WHERE>*20##at once (live F455 1.0.76,tests/fixtures/traces/issue_466), so its zones ask nothing when they are added (#674). Everything, the knob and actuator 1 included, is asked by the delayed poll above, each read answered in about 0.1 s (#466). Nothing tells which actuators a zone of an F455 has, so the poll ends with*#4*<zone>*19##: the state of both sides of the zone, whatever the number of actuators (a zone with a valve on actuator 1 and a fan coil on actuator 2 then showscoolingand its fan speed although actuator 1 is off). A repeated "off" of an actuator that was already off does not end what dimension 19 reported. The actuator numbers a zone reported are remembered across a restart, and the poll then asks for each of them instead of actuator 1 alone; an actuator the zone never reported is not asked (the F455 NACKs the read of an absent actuator only after about 9 s). A zone without a probe (an actuator-only channel) refuses the first read after about 9 s and is not asked anything else; that one read holds a command session for those 9 s, once per zone added or reloaded. - Zones Behind an
#4#IIInterface (F422): across all twelve emulated gateway firmwares inown-firmware-oracle(findings/thermo-zone-requests.md), zero gateways emit$06EC/$06E4interface-routed SCS telegrams forWHO = 4: gateways either NACK/drop#4#IIqueries, truncateZ#4#IIat#and cross-poll local zoneZon the main bus (F450,F454,F459,F460,F461,H4684,MH200,MyHomeServer1), or onMH202(1.0.24) misparse trailing#4#01as local zone 4 actuator 1 and crashcoso(SIGSEGV) on*#4*Z#4#01##. Unless anOWNdgateway profile explicitly declaressupports_interface_zone_requests = True, zones configured with an#4#IIinterface are passive: neither polls (*#4*Z#4#II##,*0##,*11##,*19##,*20##,*60##) nor writes that would strip#4#IIonto local main-bus zoneZare sent, while incoming event-session broadcasts update state normally (note that 1-digit inline shorthand3#4#1..3#4#9is normalized as zone3behind interface01..09; wire frames always use two-digit#4#01..#4#15). Dimensionless and zone-dimension polls on actuator or split addresses (Z#N,Z#0,0#N,3#Z#N) are likewise never sent.
๐ง Humidity Support & Startup Behavior¶
Climate zones equipped with integrated humidity sensors (such as BTicino Living Now or specialized probes) report relative humidity via OpenWebNet WHO = 4 Dimension 60 frames (*#4*<WHERE>*60*<HUMIDITY>##):
- Dynamic Auto-Detection: When a climate zone emits a humidity reading on the SCS bus, the integration dynamically enables humidity tracking on that entity.
- State Restoration Across Restarts: The zone remembers that it supports humidity across Home Assistant restarts and restores its last known humidity value immediately.
- Targeted Startup Query: After startup (once the initial discovery sweep finishes), only climate zones that support humidity are queried with
*#4*<WHERE>*60##to refresh the current reading. This avoids unnecessary bus traffic on zones without humidity sensors. A live F461 and a live MyHomeServer1 answer the request (F459 and F460 forward it in the firmware emulation); on F450, F453, F453AV, F454, H4684, MH200, MH200N and MH202 the emulated firmware did not forward it (own-firmware-oraclefindings/thermo-zone-requests.md, afirmware_observedverdict), so until the OWNd gateway profile statessupports_heating_humidity_requesttheir zones are not queried. Whether those gateways put a probe's humidity on the event session has not been traced; any*#4*<WHERE>*60*<HH>##event the gateway delivers still updatescurrent_humiditywithout polling. - Optional YAML Configuration: In advanced setups using legacy
/config/myhome.yaml, humidity polling can be explicitly pre-enabled on a zone by settinghumidity: trueunder the zone configuration.
๐ Legacy YAML Note¶
Note
If you are upgrading from legacy v0.9 installations and still have manual climate: blocks in /config/myhome.yaml, please refer to the v0.9.4 Legacy Climate Documentation or the Legacy YAML Migration Guide. In v2, climate zones are auto-discovered dynamically.