Skip to content

Exposing Home Assistant Entities & Clock to SCS Bus

The Expose to Bus engine allows Home Assistant to project external smart home devices, sensors, energy meters, and the system clock directly onto the Legrand / BTicino OpenWebNet SCS bus on unused addresses.

By emulating virtual OpenWebNet devices, physical wall controls, touchscreens (such as the Legrand 067292, BTicino H4890, LN4890, AM4890, or 10" touchscreens), and bus supervisors can interact with non-MyHOME devices (e.g. Philips Hue, Zigbee/Matter lamps, Sonos players, Somfy blinds, Shelly relays, and ESPHome sensors) as if they were native SCS hardware.


🌟 Common Use Cases

  1. Touchscreen Control of Non-SCS Devices (WHO = 1 & WHO = 2): Tap an icon or slider on a Legrand 067292 or BTicino H4890 wall screen to control a Zigbee, Matter, or Wi-Fi device in Home Assistant. Changes made in Home Assistant or voice assistants instantly update the status icon and LED on the wall screen.
  2. Unpopulated Physical Wall Switches (WHO = 1): Use an unused rocker on an H4652/2, H4652/3, L4652/2, or K4652M2 physical wall control configured as a point-to-point light (WHO = 1) to toggle or dim a TV, media player, smart bulb, or relay in Home Assistant. (Note: On an unpopulated 2-wire address without a physical SCS actuator, basic 2-wire pushbuttons cannot latch steady load-status LEDs and flash briefly on press due to the missing hardware link-layer ACK — see Wall-Switch LEDs & TCP Client Limitations below.)
  3. Virtual Temperature Probes (WHO = 4, gateway-dependent): On gateways whose bt_termo daemon translates #0 temperature writes onto the SCS bus (verified on F461), publish an outdoor weather service temperature, Zigbee room sensor, or ESPHome probe onto an unused zone master address (1..99, DIMENSION 0). (Rejected by F454, MH200N, MH202, and wall touchscreens such as 067292 / H4890 — see Gateway Compatibility below.)
  4. Virtual Energy & Power Meters (WHO = 18, gateway-dependent): On gateways verified for WHO = 18 dimension reports (F461), publish active power (DIMENSION 113, Watts) or energy totalizers (DIMENSION 51..54, Wh) onto OpenWebNet monitor sessions. (Cannot inject synthetic power/energy onto a physical 2-wire SCS bus for 067292 / H4890 wall touchscreens — see Gateway Compatibility below.)
  5. Bus Clock & Calendar Synchronization (WHO = 13): Keep all wall screens (067292, H4890, 10" touchscreens), thermostats, and chronothermostats on the SCS bus synchronized to Home Assistant's local time, date, and daylight saving time (DST) across all gateway models.

🛠️ How to Configure

The integration supports two methods for configuring exposed bindings: UI Config Subentries (recommended) and Declarative YAML (myhome.yaml).

Method 1: Home Assistant UI (Config Subentries)

In Home Assistant, exposed bindings are configured as Config Subentries on your gateway entry:

  1. In Home Assistant, navigate to Settings → Devices & Services → Integrations → MyHOME.
  2. Click on your gateway card (e.g. F454, 067292, or MyHomeServer1).
  3. Scroll down to the Subentries section (or click the three dots ⋮ menu in the upper corner).
  4. Click + Add exposed entity (or Expose entity to SCS bus).
  5. Complete the setup form:
Field Description Example
WHO Subsystem The OpenWebNet domain to emulate (1, 2, 4, 13, or 18). WHO 1 — Lighting / Switch / Virtual Actuator
WHERE Address Unused SCS address assigned to the button/tile in MyHOME_Suite. (Omit for WHO 13) 25 or 83
Source Entity (Optional on WHO 1/2 if custom actions are set) The Home Assistant entity providing state and commands. light.hue_living_room
State Attribute (Optional) Entity attribute providing the value (brightness for WHO = 1 dimmers; current_position for WHO = 2 covers). brightness
OpenWebNet Dimension (Optional) Dimension selector (0 for temperature; 51..54 / 113 for energy/power; 0, 1, 22 for clock). (Not used for WHO 1 or WHO 2) 0
Cooldown (Optional) Rate-limiting debounce window in seconds (default: 1.0 s). 1.0
Minimum Delta (Optional) Deadband threshold; changes smaller than this value are not sent. 0.5
Periodic Broadcast Interval (Optional) Interval in seconds for recurring heartbeat broadcasts. 60
Respond to Bus Queries Reply to incoming *#WHO*WHERE...## status and dimension read requests (default: true). true
Bidirectional Act on incoming WHO = 1 / WHO = 2 bus commands and wall-switch presses (default: true). true
Brightness Step (%) Relative step size (1..100%) applied per WHO = 1 dimmer step-up / step-down command (default: 10%). 25
Custom 'On' States (Optional) Comma-separated list of states considered ON (e.g. on, playing, open). on, playing
Value Template (Optional) Jinja2 template to extract or transform values before publishing. {{ value \| round(1) }}
Turn-on / Turn-off / Step-up / Step-down Actions (Optional) Visual Home Assistant action sequences overriding default entity service calls (turn_on / turn_off for WHO = 1 & WHO = 2; step_up / step_down for WHO = 1; hidden for WHO = 4, 13, and 18). media_player.volume_up

Click Submit. The binding activates immediately without requiring a Home Assistant restart.


Method 2: Declarative YAML (myhome.yaml)

You can also define exposed bindings in /config/myhome.yaml under your gateway's MAC address (on single-gateway installations, expose: can also sit directly at the top level of /config/myhome.yaml):

# /config/myhome.yaml
"00:03:50:01:02:03":   # Your Gateway MAC address (optional on single-gateway setups)
  expose:
    # -----------------------------------------------------------------
    # 1. Virtual Light / Dimmer (WHO = 1)
    # Short press on WHERE "83" turns the smart bulb ON/OFF; holding up/down
    # steps brightness by 25%. Setting 'attribute: brightness' also mirrors
    # brightness level changes back onto the bus.
    # -----------------------------------------------------------------
    - who: 1
      where: "83"
      entity_id: light.smart_bedroom
      attribute: brightness
      bidirectional: true
      brightness_step_pct: 25
      cooldown: 0.5

    # -----------------------------------------------------------------
    # 2. Virtual Cover / Shutter (WHO = 2)
    # Tapping up/down/stop on wall screen at WHERE "31" controls pergola curtain.
    # -----------------------------------------------------------------
    - who: 2
      where: "31"
      entity_id: cover.pergola_curtain
      bidirectional: true

    # -----------------------------------------------------------------
    # 3. Virtual Temperature Probe (WHO = 4, Dimension 0)
    # Publishes outdoor temperature onto unused zone master address 50
    # (1..99 required on F461 / bt_termo; 100..900 only on reply-injection gateways).
    # -----------------------------------------------------------------
    - who: 4
      where: "50"
      dimension: 0
      entity_id: sensor.outdoor_temperature
      cooldown: 5.0
      min_delta: 0.2
      periodic_send: 60

    # -----------------------------------------------------------------
    # 4. Virtual Active Power Meter (WHO = 18, Dimension 113)
    # Publishes grid active power (W) onto meter address 51.
    # Auto-converts kW -> W if the sensor unit of measurement is kW.
    # -----------------------------------------------------------------
    - who: 18
      where: "51"
      dimension: 113
      entity_id: sensor.grid_active_power
      cooldown: 2.0
      min_delta: 10.0

    # -----------------------------------------------------------------
    # 5. Virtual Energy Counter / Totalizer (WHO = 18, Dimension 51)
    # Publishes cumulative grid energy totalizer (Wh) onto meter address 51.
    # Auto-converts kWh -> Wh if the sensor unit of measurement is kWh.
    # -----------------------------------------------------------------
    - who: 18
      where: "51"
      dimension: 51
      entity_id: sensor.grid_energy_consumed
      cooldown: 5.0
      min_delta: 100.0   # Broadcast on 100 Wh increments

    # -----------------------------------------------------------------
    # 6. Bus Clock & DST Sync (WHO = 13, Dimension 22)
    # Broadcasts atomic time, date, and calendar once every hour.
    # Note: Set 'periodic_send: 0' for query-only mode (answers *#13** reads
    # without proactive pushes, ideal for NTP-synchronized gateways).
    # -----------------------------------------------------------------
    - who: 13
      dimension: 22
      periodic_send: 3600
      respond_to_read: true

💡 Virtual Dimmers & MyHOME_Suite Wall Control Modes (WHO = 1 vs CEN+)

When using a physical 2-wire SCS wall control (such as BTicino H4652/2, L4652/2, AM5832/2, K4652M2, or Legrand 067552) to dim a Home Assistant light on an unpopulated SCS address (an address with no physical BTicino actuator wired on the 2-wire bus):

In MyHOME_Suite, configure the wall control channel as Light control (Object 400, Beleuchtung/schalten) with Point-to-point addressing (A / PL, e.g. A = 8, PL = 3 → WHERE = 83) and either of the two standard two-button (O/I) dimmer modalities:

  • ON/OFF and point to point dimming (M = 9 — German: "ON/OFF und Regelung nur Punkt-Punkt"; identical to physical configurator M = O/I)
  • ON/OFF and dimming (M = 3 — German: "EIN/AUS und Dimmerregelung")

Both modalities work identically for a point-to-point virtual dimmer:

  • Short press UP / DOWN: Sends *1*1000#1*WHERE## / *1*1000#0*WHERE## to turn the Home Assistant entity ON or OFF and mirrors *1*1*WHERE## / *1*0*WHERE## onto the bus (updating WHO = 1 tiles on wall touchscreens such as 067292, H4890, and L4684).
  • Hold DOWN: Sends *1*1000#31*WHERE## and steps brightness down by brightness_step_pct (or runs step_down_action).
  • Hold UP: Because no physical SCS dimmer hardware-ACKs the unpopulated address on the 2-wire bus, H4652/2 repeats *1*1000#1*WHERE## every ~2 seconds (with a ~200 ms SCS link-layer retry per step) instead of switching to *1*1000#30*WHERE##. ExposeManager automatically deduplicates the ~200 ms SCS retries and treats consecutive held *1*1000#1*WHERE## frames (1.6–3.0 s apart while the bound entity is already on) as step_up (+brightness_step_pct or step_up_action), while keeping single taps, quick double-presses, and turn-on from off idempotent.

Tip

Want faster (~0.5 s) smooth dimming without the ~2 s unacknowledged SCS timeout? On H4652/2 / L4652/2 / 067552 / K4652M2, you can alternatively configure the module in MyHOME_Suite as Scheduled scenario PLUS (CEN+, WHO = 25, Object 406) instead of WHO = 1 Expose. CEN+ frames are broadcast events (*25*21#<btn>*2<addr>## short press, 22 hold start, 23 ~0.5 s hold repeat, 24 hold release) that require no physical actuator ACK on the 2-wire bus and appear directly as Home Assistant device triggers — at the trade-off that CEN+ buttons do not track WHO = 1 load-state LEDs or Area/General light commands.

2. Hardware Limitations on Unpopulated WHO = 1 Addresses (Wall-Switch LEDs & TCP Clients)

When WHERE is a purely virtual WHO = 1 address with no physical SCS actuator wired on the 2-wire bus, two hardware/firmware constraints of the 2-wire SCS bus and OpenWebNet gateways (MH201, MH200N, F454, F453, F461, MyHomeServer1, H4684) apply:

  1. Basic 2-Wire Pushbutton LEDs (H4652/2, H4652/3, L4652/2, AM5832/2):
  2. Missing ~35 ms 2-wire link-layer hardware ACK: When a physical WHO = 1 pushbutton sends a unicast command (A8 <WHERE> 00 12 <00|01> <xor> A3), it waits ~35 ms for the target physical SCS actuator to assert a hardware link-layer ACK (0xA5 / PIC $08). Because no physical actuator occupies WHERE (and OpenWebNet IP gateways are passive bus peers that do not synthesize link-layer ACKs for arbitrary unpopulated addresses), the wall switch retransmits once ~200 ms later and flashes its LED to indicate a delivery fault / unpopulated address (on multi-channel controls such as H4652/3 with shared indicator logic, this fault flash can also blank an adjacent channel's LED until that native actuator next reports its status).
  3. Command telegram (<WHERE> 00 12 <00|01>) vs. Actuator Status broadcast (B8 <WHERE> 12 <00|01>): Although OpenWebNet TCP uses *1*1*WHERE## / *1*0*WHERE## for both commands and status events, on the 2-wire SCS bus they are distinct telegram opcodes. Every OpenWebNet gateway firmware translates outbound TCP *1*1*WHERE## / *1*0*WHERE## into an SCS command telegram ($03 <WHERE> 00 12 <00|01>\r), never into a 0xB8 actuator status broadcast (B8 <WHERE> 12 <00|01>), which is only emitted by a physical SCS actuator. While wall touchscreens (067292, H4890, L4684, 10" screens) update their UI tiles from command/translation frames, basic 2-wire pushbuttons only latch steady load-status LEDs from 0xB8 actuator status broadcasts.
  4. How to avoid the LED error flash: Configure the pushbutton channel as CEN (WHO = 15) or CEN+ (WHO = 25, Object 406) instead of WHO = 1. Scenario frames are connectionless broadcast events that expect no point-to-point actuator ACK on the 2-wire bus, so pressing the button never triggers an error flash (at the trade-off that CEN/CEN+ buttons do not maintain stateful load LEDs).
  5. External OpenWebNet TCP Clients (iMyHome, Third-Party Apps) & Bus Monitor Injection:
  6. Physical 2-wire devices (wall switches and 2-wire wall screens) transmit on the 2-wire SCS wire, entering the gateway from the bus transceiver side ($17 ...) and forwarding to Home Assistant's TCP event monitor session (*99*1##) as *1*1000#1*WHERE## or *#1*WHERE##.
  7. By contrast, frames sent on a TCP command session (*99*0##) by external TCP clients (such as the iMyHome app) or by Home Assistant's Bus Monitor transmit tool (ws_bus_monitor_send) are written out to the 2-wire transceiver ($03 <WHERE> 00 15 00\r for *#1*WHERE##, $03 <WHERE> 00 12 00\r for *1*1*WHERE##). OpenWebNet gateways (MH201, MH200N, F454, F461, MyHomeServer1) do not loop TCP command-session status reads (*#1*WHERE##) or unpopulated WHO = 1 commands back onto TCP event monitor sessions (*99*1##) unless a physical actuator on the 2-wire bus replies with B8 <WHERE> 12 <state>. Consequently, iMyHome receives NACK (*#*0##) on *#1*WHERE## (displaying the unpopulated light as greyed out), and Bus Monitor command-session injections (*1*1*WHERE##, *#1*WHERE##) record TX without reaching ExposeManager.

🎛️ Advanced: Custom Script Actions

For complex integrations (such as cycling media playlists, executing sequences, or calling third-party services with conditions), you can configure turn_on_action, turn_off_action, step_up_action, and step_down_action either directly in the UI Config Subentry action pickers or in myhome.yaml using Home Assistant's native Script syntax:

# /config/myhome.yaml
"00:03:50:01:02:03":
  expose:
    - who: 1
      where: "95"
      entity_id: media_player.kitchen_sonos
      on_states:
        - playing
      turn_on_action:
        - action: media_player.play_media
          target:
            entity_id: media_player.kitchen_sonos
          data:
            media_content_id: "http://icecast.radiofrance.fr/fip-midfi.mp3"
            media_content_type: "audio/mp3"
      turn_off_action:
        - action: media_player.media_pause
          target:
            entity_id: media_player.kitchen_sonos
      step_up_action:
        - action: media_player.volume_up
          target:
            entity_id: media_player.kitchen_sonos
      step_down_action:
        - action: media_player.volume_down
          target:
            entity_id: media_player.kitchen_sonos

Action Script Variables & Templates

During script execution, the following template variables are available:

  • {{ this.state }}: The current state of the source entity.
  • {{ entity_id }}: The entity ID of the bound entity.
  • {{ who }}: The OpenWebNet WHO subsystem integer (1 or 2).
  • {{ where }}: The bound SCS WHERE address string.

Tip

{{ who }} and {{ where }} are especially useful when sharing a single reusable Home Assistant script or automation action across multiple exposed wall keys or virtual actuators.


🔬 How the Expose Engine Works

flowchart TD
    subgraph HA["Home Assistant"]
        State["State Change Event<br>(e.g. Light ON / Temp 21.5°C)"]
        Script["Custom Action Script<br>(turn_on_action)"]
    end

    subgraph Engine["ExposeManager & Echo Guard"]
        Filter{"Deadband & Cooldown<br>|Δ| >= min_delta?"}
        Scheduler["FrameScheduler<br>(Write Future Bound)"]
        EchoGuard["Echo Guard (1.5s TTL)<br>Absorbs translations & loops"]
    end

    subgraph Bus["OpenWebNet SCS Bus"]
        GW["Gateway Socket<br>(TCP port 20000)"]
        Screen["Legrand 067292 / BTicino H4890<br>(Wall Screen / Physical Key)"]
    end

    State --> Filter
    Filter -->|Pass| Scheduler
    Scheduler -->|Dispatch Frame| GW
    GW --> Screen
    GW -.->|Bus Echo| EchoGuard
    EchoGuard -.->|Absorb Loopback| Engine

    Screen -->|Button Press Frame| GW
    GW --> Engine
    Engine -->|Trigger Action| Script
    Engine -->|Update Target| State

Key Architectural Invariants

  1. Write-Future-Bound Echo Guarding: When Home Assistant sends a state mirror frame to the bus (e.g. *1*1*25## or *#2*25*#11#001*50##), gateways broadcast multi-frame translation echoes back onto the monitor session (*1*1000#1*25##, *2*1000#0*25##, *#2*25*#11#001#1*50##). The Expose engine tracks pending write futures and arms an echo-guard with a 1.5 s TTL to absorb these loops, preventing self-oscillations.
  2. Trailing-Edge Debouncing: Rapid state changes (such as slider dragging in Home Assistant) are debounced within the cooldown window. Once the cooldown timer expires, the latest state is sent (eventual consistency).
  3. Queue Superseding: A high-priority user command or wall-button press immediately supersedes any pending mirror frame for the same target, ensuring that an outdated state change never arrives after a button press.

🏛️ Gateway Compatibility & Firmware Verification

Different gateway models handle bus frame injection differently:

OpenWebNet Domain Gateway Compatibility Required Frame Form Notes
WHO = 1 (Lights / Switches) All Gateways *#1*WHERE*#1*LEVEL*0## (or *1*1*WHERE## / *1*0*WHERE##) Universal support for wall touchscreens (067292, H4890, L4684) and physical 2-wire wall-switch input (*1*1000#1/0*WHERE##) across F454, F455, F459, MH200N, MH201, MH202, MHS1, F461, 067292, and H4890. On unpopulated addresses without a physical SCS actuator, basic 2-wire pushbuttons (H4652/2, H4652/3) do not receive 0xB8 actuator status / link-layer ACKs for steady LEDs, and TCP command-session clients (iMyHome) are not looped back to event sessions.
WHO = 2 (Covers / Shutters) All Gateways *#2*WHERE*#11#001*POS## (or *2*1/2/0*WHERE##) Universal support; translation echoes are cleanly absorbed.
WHO = 13 (Clock & DST) All Gateways *#13**#22*H*M*S*T*W*D*M*Y## Synchronizes on-screen clocks across all models (067292, H4890, F454, etc.). Set periodic_send: 0 for query-only mode.
WHO = 4 (Virtual Temperature) Verified on F461 (WHERE 1..99) *#4*WHERE*#0*TTTT## bt_termo (F461) translates unused zone master addresses 1..99 (e.g. "50") onto the SCS bus (D1 <ZZ> 03 02 F0 <TT> <TT> 00), but rejects 3-digit probe addresses (100..900). Rejected (NACK) for all addresses on F454, F459, MH200N, MH202, 067292, H4890, and H4684.
WHO = 18 (Virtual Energy Meter) Verified on F461 (TCP session only) *#18*WHERE*113*WATT## Rejected (NACK) by wall touchscreens (067292, H4890, H4684). bt_supervisione / bt_energy gateways (F454, F459, MH200N, MH202, MHS1, F461) ACK on TCP but emit an SCS active-power read request (D1 A1 02 33 00 1D 00 00), discarding the value — so synthetic WHO = 18 readings cannot reach physical 2-wire SCS wall screens.

Note

For physical wall touchscreens (Legrand 067292, Arteor 573958, BTicino H4890, LN4890), configure virtual light/switch (WHO = 1), shutter (WHO = 2), or scenario tiles with unused point-to-point addresses in MyHOME_Suite, and add clock sync (WHO = 13). On a shared SCS bus with a primary gateway (e.g. F454 + 067292), create the expose subentries on the primary gateway and keep WHO = 4 / WHO = 18 undelegated on the primary gateway.


🔍 Diagnostics & Troubleshooting

  • Check Active Bindings: Open Settings → Devices & Services → MyHOME → Download Diagnostics. The JSON file contains an "expose" section detailing all active bindings, throttles, and last-sent timestamps.
  • Unsupported / Unverified Gateway Warning: The UI Config Subentry flow hides WHO = 4 and WHO = 18 on gateways whose firmware cannot inject them onto the SCS bus, and rejects 3-digit WHO = 4 probe addresses (100..900) on #0-only gateways (F461). If a legacy YAML or pre-existing binding targets an unsupported gateway or address, a single warning is logged at startup ("Expose WHO=... is disabled: gateway ... Nothing is sent for this binding").
  • Duplicate Address Error (invalid_expose): Each (who, where, dimension) triplet must be unique per gateway.