Known Limitations¶
Things the integration does not do, or does with a caveat, and the reason. Where a limitation is a design decision it links to the discussion; where it is a gap it names the trace or hardware needed to close it (see the Roadmap and RFC #248). The full feature matrix is in Supported Functions.
Bus and gateway¶
| Limitation | Why | Workaround |
|---|---|---|
One command session per gateway on MH200 / MH200N / MH201 / F452 / F453 / F453AV / H4684 / H4890. Commands are queued and paced (150 ms on MH200 / MH200N / F452 / F453 / F453AV, 100 ms on MH201, 50 ms on H4684 / H4890). |
Those gateways refuse or drop overlapping sessions; the pacing is what keeps them alive. | Keep the worker count at the profile default (1). F454, F455, F461, MyHomeServer1 (up to 4) and MH202 (up to 2) take more workers. |
| Entities can be unavailable for up to 60 s after a gateway drop. | The availability grace period hides short reconnects instead of flapping every entity. | Nothing needed; a longer outage marks entities unavailable and they recover on reconnect. |
| A gateway's model can be mislabelled. | Only the WHO 13 device-type reply is available in-band, and its official table stops at 2006 hardware. | The identification rules correct manual choices and raise a repair issue when evidence contradicts SSDP; open Configure (Options Flow) to set the hardware model explicitly (Reconfigure updates host/port/password). |
USB / serial gateways (Legrand 3578 / 088328 OpenZigBee) are not supported in v2.0. |
Deferred out of v2.0.0 (Discussion #879): OWNd sessions open TCP sockets only, OpenZigBee <id>#9 addressing is not wired end-to-end, and no physical serial capture has been verified. |
Connect via a supported TCP/IP OpenWebNet gateway, or contribute a raw serial capture on #466 for v2.1+. |
| No HMAC on MH200 / MH200N / MH201 / F452 / F453 / F453AV / H4684 / AM4890 / H4890. | Those gateways only implement the legacy numeric (SHA-less) OPEN password; SHA-256 HMAC is supported on F454, F455, F461, MH202, and MyHomeServer1. |
Configure the numeric OpenWebNet password on legacy gateways. |
| Broadcast, Area 00, and General 0 frames do not generate entities. | Broadcast frames (WHERE="0", "00") coordinate multiple actuators and do not represent individual physical devices (except WHO 5 where WHERE="0" is the alarm central unit). Creating entities from these frames produced phantom entities like sensor.zone_00 or climate.climate_zone_00. |
Control individual actuators or use YAML declared groups (where: '#G' under light:) and manual scenes. |
Secondary energy meters (52–59) require bus activity or manual configuration for initial setup. |
Startup discovery queries factory default meter 51 (*#18*51*51##, *#18*51*113##) to avoid long startup sweep delays. |
Secondary meters appear automatically when they transmit power/energy readings on the bus, or immediately when running myhome.sweep_bus. They can also be declared in myhome.yaml. |
Lighting (WHO 1)¶
| Limitation | Why | Workaround |
|---|---|---|
| Group, area and general commands from wall switches re-sync with a ~500 ms delay, and only areas with a known light. (P7, #368) | A 500 ms (RESYNC_DEBOUNCE_S = 0.5) debounced re-sync (see runtime behaviour) only sweeps *#1*A## per area/group, or skips the sweep entirely if the gateway already echoed each member's status; there is still no trace from a gateway that echoes nothing to confirm the fallback is sufficient there. |
Disable Sweep group/area/general light addresses for status in the Options Flow if your gateway needs a different cadence, and report a bus trace on #368. |
A declared group (where: '#G' in myhome.yaml) never auto-discovers its membership. (P7, #368) |
OpenWebNet has no command to read back which actuators a group was programmed with - that is set on the plant itself (MyHOME_Suite or a physical group-programmed actuator), not on the bus. | Declare members: yourself if you want derived on/off, brightness and colour state; without it the entity is assumed_state and shows separate On/Off controls. |
| Colour modes are learned, not configured. A DALI DT8 light shows colour temperature only after its first dimension 14 frame. | The bus does not describe an actuator's capabilities; it only reports what it does. | Set color_temp: true / rgb: true / hs: true in myhome.yaml to declare the mode up front. |
| Native transitions depend on the actuator. | Some dimmers ignore the fade parameter. | Keep the default software_stepped transition mode. |
| Physical sensors sharing an actuator address (e.g. 3477 twilight photocell) trigger the actuator directly on the wire. | Point-to-point SCS physical addressing binds the sensor contact interface directly to the relay. Hardware turn-ons cannot be prevented before they execute on the bus. | Use the Hardware-Coupled Sensors Guide and Dusk Curfew Blueprint to enforce bedtime curfews and companion synchronization, or decouple the sensor address. |
Covers (WHO 2)¶
| Limitation | Why | Workaround |
|---|---|---|
| Timed covers report a calculated position. It drifts if the motor runs at a different speed than assumed, or after a manual stop mid-travel. | The actuator has no encoder; only position-reporting actuators (dimension 10) know where the shutter is. | Calibrate with myhome.calibrate_cover (or myhome.set_cover_travel_time); a full open or close resynchronises the estimate. |
| Calibration on an MH200 / MH200N can fail with no stop status from the actuator, and configurator run-time cut-offs (60 s, 120 s, …) are refused. | The single-session gateway delays or drops the actuator's stop status; actuators at a whole-minute configurator limit stop on their timer rather than at the end stop. | Measure the run with a stopwatch and store the timings via myhome.set_cover_travel_time. |
| One calibration at a time per gateway. | Two motors on one paced session make the timings meaningless. | Queue is automatic; myhome.stop_cover_calibration cancels it. |
| Rapid concurrent point-to-point commands behind an F422 interface can drop frames. | The physical F422 interface internal FIFO buffer and secondary SCS bus arbitration saturate under rapid unpaced bursts. | Use native General broadcast covers (where: '0', interface: '<id>') which send a single OpenWebNet broadcast (*2*WHAT*0#4#<id>##), or rely on the integration's automatic 0.3 s paced member fan-out for position control. See Covers. |
Timed Venetian slat tilt (slat_tilt / slat_time) is dead-reckoned on every actuator. |
WHO 2 has no slat-angle field: Dimension 10 reports status, level, priority and info, and Dimension 11 is the go-to-level write. The slat angle is therefore an estimate from slat_time on every actuator, including the advanced ones (F401, LN4661M2, 067557), whose Dimension 10 position reports are only used to time that estimate. |
Configure slat_time for timed Venetian blinds; a full open or close resynchronises the slat estimate. |
Thermoregulation (WHO 4)¶
| Limitation | Why | Workaround |
|---|---|---|
| Weekly programs, holiday and scenario modes are not exposed. | Only manual set-point, auto, off and the seasonal modes are modelled on the climate entity. | myhome.send_message with the central-unit mode frame (*4*<mode>*#0##). |
4-zone central unit 4695 (#0#1) is verified on synthetic frames only. |
No community trace from a 4695 plant yet. | Please attach a trace to RFC #248 if you own one. |
| A commanded setpoint (dimension 14) that arrives without a following dimension 12 does not update the slider once the zone has reported a setpoint in force. | The slider follows dimension 12 (the setpoint the thermostat regulates to, knob offset included) as soon as the zone has reported it; a dimension 14 that is not the echo of a write from Home Assistant is kept as the commanded value only. Both captured plants (F461 2.0.11 with a KW4691, MyHomeServer1 3.87.13 with 36 zones) emit dimension 12 after every write and after every local change, so the slider stays current there; a gateway that echoed only dimension 14 for an external change would leave the slider on the previous value until the next dimension 12 report or poll. | Reload the entity (homeassistant.update_entity) to poll *#4*Z##; please attach a trace if you see this. |
Probes (WHERE ≥ 100) are read-only and push-driven. |
They NACK the explicit poll (*#4*ZPP*15##) and push readings on their own schedule. |
Nothing needed; a probe that goes silent is polled again after 5 min. |
Burglar alarm (WHO 5)¶
| Limitation | Why | Workaround |
|---|---|---|
Zones are not individual entities; the panel follows the central unit (3485 / 3486). Some plants (F454 + 3486) emit zone status frames without exposing direct OpenWebNet arm / disarm commands (#311). |
OpenWebNet WHO 5 central units reject unauthenticated TCP arm/disarm writes by design; the integration models the central unit as a read-only panel (with optional WHO 9 AUX arm/disarm bridges) validated against physical 3486 and MH202 captures. |
Individual zone frames are available as myhome_message_event (with Generate Events on) and alarm state changes as myhome_alarm_event. |
| Arming requires the central unit to accept the command. | Central units reject arming while a zone is open or the engineer code is active; the bus only reports the refusal. | Watch the bus-monitor card for the NACK. |
Door entry and intercom (WHO 6 / WHO 8)¶
| Limitation | Why | Workaround |
|---|---|---|
Gateways whose firmware routes no WHO 6 reject unlock commands (*6*10*<where>##) with NACK (*#*0##): MyHomeServer1, F455, F461, F450, F460, and the A/V gateways F454 / F459. (Discussion #833) |
MyHomeServer1, F450, F455, F460 and F461 ship no bt_vct door-entry translator, so they also see no WHO 6 / 8 traffic. F454 (and F459, which ships the same firmware image) routes only WHO 8 to bt_vct: it reports doorbells, but no program takes WHO 6. |
Either wire an MH-bus dry-contact relay actuator (F411/2, F411/1N, or F411/4 via interposing relays since F411/4 shares a common C terminal across its 4 channels) in parallel with the gate/strike dry-contact input and configure it as a WHO 1 impulse cover, or add a gateway that routes WHO 6 and sees the door-entry riser (MH200, MH202 or F453, with the riser reaching its bus, e.g. through an F422 interface) as a Shared Bus → Secondary gateway with WHO 6 (and WHO 8 for doorbells) delegated to it. F453AV ships bt_vct, but its WHO 6 routing is unverified. |
HomeTouch 3488 indoor video displays neither bridge AV frames onto MH nor expose a local OpenWebNet server on TCP port 20000. (Discussion #833) |
HomeTouch 3488 has physically isolated MH SCS BUS and AV SCS BUS 2-wire terminals: tapping its screen for lights transmits on MH, while door/gate release buttons transmit strictly on AV. Over LAN, 3488 acts only as an OpenWebNet client pairing to MyHomeServer1 and exposes SIP/HTTPS for the BTicino cloud Door Entry for HOMETOUCH app — no local openserver listens on port 20000. |
Do not point the integration's host IP at HomeTouch 3488. Use an MH-bus dry-contact impulse relay (F411/2, F411/1N) at the gate/strike inputs or a WHO 6-capable gateway that sees the door-entry riser (see above). |
Door entry locks (lock) are never auto-discovered from bus traffic. |
Creating a code-less lock entity automatically whenever someone presses an indoor door-release button would let anyone with dashboard access unlatch the strike. |
Declare door entry locks explicitly under lock: in myhome.yaml (with an optional code: PIN). |
Sound system (WHO 16 / WHO 22)¶
| Limitation | Why | Workaround |
|---|---|---|
| Streaming needs a network decoder per concurrent stream. With two decoders mapped, a third room asks for All audio matrix inputs are currently in use. | The F441 matrix routes one physical input per source; the integration claims one decoder per playing zone. | Map more decoders in the options flow, or group rooms on the decoder side. |
| Removing the group leader interrupts the music briefly. Unticking the leader in Music Assistant, or turning it off (Home Assistant or wall panel), stops the sound for a few seconds before the remaining rooms resume. | Music Assistant owns one queue per player and can only move it by stopping it and starting a new stream on another player; a powered-off player cannot keep a queue. The bus itself is not interrupted: MyHOME switches only the leader's amplifier off and hands the decoder to the next room. See Why deselecting the group leader gives a short gap. | Play to a Music Assistant Sync Group with Dynamic members on, so any room can be ticked and unticked; see Recommended: one Music Assistant Sync Group for the house. With temporary groups, play to a room that stays on: removing a member never interrupts anything. |
Gateways that speak only WHO 22 (MyHomeServer1, F461) expose declared F500 / F500N FM tuners, not room amplifier zones. |
Those gateways ship bt_multi without bt_difson and reject every WHO 16 frame. F500 / F500N tuner sources (2#S / 5#2#S) are fully controlled and decoded over WHO 22, and dual-stack gateways also track WHO 22 area-source routing (4#<area>), whereas room amplifier discovery and zone power/volume/routing commands (01–99) require WHO 16. |
On a shared bus, pair a WHO 16-capable secondary gateway (such as MH200N, MH202, F454, H4890, or H/L4684 FW ≥ 6.0.0 for coupled WHO 16 / WHO 22, or MH200 for WHO 16) with audio delegated to it. |
Scenario buttons (WHO 15 / 25)¶
| Limitation | Why | Workaround |
|---|---|---|
| CEN / CEN+ devices are stateless. They have no entity, only device triggers. | Pushbuttons report presses, holds, releases and rotary steps rather than a persistent on/off state. | Use the device triggers (see CEN & CEN+) or the community blueprint. |
Home Assistant integration surface¶
| Limitation | Why | Workaround |
|---|---|---|
entity_name in myhome.yaml only applies to sensors and binary sensors. On a light, switch, cover, thermostat, audio zone or alarm panel it is ignored: those entities are their device and carry the device name. |
Home Assistant's device / entity naming model; entity_name never named those platforms in earlier versions either. |
Rename the device in the UI, or change name. |
Fresh installs name sensor ids after the device class (sensor.house_power, binary_sensor.cancello_opening) where earlier pre-releases produced sensor.house, sensor.house_2, binary_sensor.cancello. |
Earlier pre-releases used the device name with numeric suffixes for the second and third sensor of a device. | Existing installations keep their ids; automations on a fresh install use the new ids. |
| Strict typing is complete. | mypy --strict is enforced with zero errors across all integration modules (Platinum Quality Scale). |
— |
myhome.yaml is a compatibility path, not the primary configuration. Devices are discovered from the bus; YAML only adds names, device classes and options. |
v2 is UI-first. | Keep myhome.yaml for names and travel_time; delete devices you no longer want from the device page. |
| Deleting a device does not stop it from coming back. | Devices are re-discovered from bus traffic; a device that still exists reappears on its next status frame. | Only delete devices that are physically gone. |
Home Assistant 2026.8 or newer is required (hacs.json). |
Current cores require Python 3.14 and modern via_device_id, repairs, and HTTP server APIs. |
Upgrade Home Assistant Core to 2026.8 or newer before installing MyHOME v2.0. |