Skip to content

Known Limitations

Things the integration does not do, or does with a caveat, and the reason. Where a limitation is a design decision it links to the discussion; where it is a gap it names the trace or hardware needed to close it (see the Roadmap and RFC #248). The full feature matrix is in Supported Functions.

Bus and gateway

Limitation Why Workaround
One command session per gateway on MH200 / MH200N / MH201 / F452 / F453 / F453AV / H4684 / H4890. Commands are queued and paced (150 ms on MH200 / MH200N / F452 / F453 / F453AV, 100 ms on MH201, 50 ms on H4684 / H4890). Those gateways refuse or drop overlapping sessions; the pacing is what keeps them alive. Keep the worker count at the profile default (1). F454, F455, F461, MyHomeServer1 (up to 4) and MH202 (up to 2) take more workers.
Entities can be unavailable for up to 60 s after a gateway drop. The availability grace period hides short reconnects instead of flapping every entity. Nothing needed; a longer outage marks entities unavailable and they recover on reconnect.
A gateway's model can be mislabelled. Only the WHO 13 device-type reply is available in-band, and its official table stops at 2006 hardware. The identification rules correct manual choices and raise a repair issue when evidence contradicts SSDP; open Configure (Options Flow) to set the hardware model explicitly (Reconfigure updates host/port/password).
USB / serial gateways (Legrand 3578 / 088328 OpenZigBee) are not supported in v2.0. Deferred out of v2.0.0 (Discussion #879): OWNd sessions open TCP sockets only, OpenZigBee <id>#9 addressing is not wired end-to-end, and no physical serial capture has been verified. Connect via a supported TCP/IP OpenWebNet gateway, or contribute a raw serial capture on #466 for v2.1+.
No HMAC on MH200 / MH200N / MH201 / F452 / F453 / F453AV / H4684 / AM4890 / H4890. Those gateways only implement the legacy numeric (SHA-less) OPEN password; SHA-256 HMAC is supported on F454, F455, F461, MH202, and MyHomeServer1. Configure the numeric OpenWebNet password on legacy gateways.
Broadcast, Area 00, and General 0 frames do not generate entities. Broadcast frames (WHERE="0", "00") coordinate multiple actuators and do not represent individual physical devices (except WHO 5 where WHERE="0" is the alarm central unit). Creating entities from these frames produced phantom entities like sensor.zone_00 or climate.climate_zone_00. Control individual actuators or use YAML declared groups (where: '#G' under light:) and manual scenes.
Secondary energy meters (52–59) require bus activity or manual configuration for initial setup. Startup discovery queries factory default meter 51 (*#18*51*51##, *#18*51*113##) to avoid long startup sweep delays. Secondary meters appear automatically when they transmit power/energy readings on the bus, or immediately when running myhome.sweep_bus. They can also be declared in myhome.yaml.

Lighting (WHO 1)

Limitation Why Workaround
Group, area and general commands from wall switches re-sync with a ~500 ms delay, and only areas with a known light. (P7, #368) A 500 ms (RESYNC_DEBOUNCE_S = 0.5) debounced re-sync (see runtime behaviour) only sweeps *#1*A## per area/group, or skips the sweep entirely if the gateway already echoed each member's status; there is still no trace from a gateway that echoes nothing to confirm the fallback is sufficient there. Disable Sweep group/area/general light addresses for status in the Options Flow if your gateway needs a different cadence, and report a bus trace on #368.
A declared group (where: '#G' in myhome.yaml) never auto-discovers its membership. (P7, #368) OpenWebNet has no command to read back which actuators a group was programmed with - that is set on the plant itself (MyHOME_Suite or a physical group-programmed actuator), not on the bus. Declare members: yourself if you want derived on/off, brightness and colour state; without it the entity is assumed_state and shows separate On/Off controls.
Colour modes are learned, not configured. A DALI DT8 light shows colour temperature only after its first dimension 14 frame. The bus does not describe an actuator's capabilities; it only reports what it does. Set color_temp: true / rgb: true / hs: true in myhome.yaml to declare the mode up front.
Native transitions depend on the actuator. Some dimmers ignore the fade parameter. Keep the default software_stepped transition mode.
Physical sensors sharing an actuator address (e.g. 3477 twilight photocell) trigger the actuator directly on the wire. Point-to-point SCS physical addressing binds the sensor contact interface directly to the relay. Hardware turn-ons cannot be prevented before they execute on the bus. Use the Hardware-Coupled Sensors Guide and Dusk Curfew Blueprint to enforce bedtime curfews and companion synchronization, or decouple the sensor address.

Covers (WHO 2)

Limitation Why Workaround
Timed covers report a calculated position. It drifts if the motor runs at a different speed than assumed, or after a manual stop mid-travel. The actuator has no encoder; only position-reporting actuators (dimension 10) know where the shutter is. Calibrate with myhome.calibrate_cover (or myhome.set_cover_travel_time); a full open or close resynchronises the estimate.
Calibration on an MH200 / MH200N can fail with no stop status from the actuator, and configurator run-time cut-offs (60 s, 120 s, …) are refused. The single-session gateway delays or drops the actuator's stop status; actuators at a whole-minute configurator limit stop on their timer rather than at the end stop. Measure the run with a stopwatch and store the timings via myhome.set_cover_travel_time.
One calibration at a time per gateway. Two motors on one paced session make the timings meaningless. Queue is automatic; myhome.stop_cover_calibration cancels it.
Rapid concurrent point-to-point commands behind an F422 interface can drop frames. The physical F422 interface internal FIFO buffer and secondary SCS bus arbitration saturate under rapid unpaced bursts. Use native General broadcast covers (where: '0', interface: '<id>') which send a single OpenWebNet broadcast (*2*WHAT*0#4#<id>##), or rely on the integration's automatic 0.3 s paced member fan-out for position control. See Covers.
Timed Venetian slat tilt (slat_tilt / slat_time) is dead-reckoned on every actuator. WHO 2 has no slat-angle field: Dimension 10 reports status, level, priority and info, and Dimension 11 is the go-to-level write. The slat angle is therefore an estimate from slat_time on every actuator, including the advanced ones (F401, LN4661M2, 067557), whose Dimension 10 position reports are only used to time that estimate. Configure slat_time for timed Venetian blinds; a full open or close resynchronises the slat estimate.

Thermoregulation (WHO 4)

Limitation Why Workaround
Weekly programs, holiday and scenario modes are not exposed. Only manual set-point, auto, off and the seasonal modes are modelled on the climate entity. myhome.send_message with the central-unit mode frame (*4*<mode>*#0##).
4-zone central unit 4695 (#0#1) is verified on synthetic frames only. No community trace from a 4695 plant yet. Please attach a trace to RFC #248 if you own one.
A commanded setpoint (dimension 14) that arrives without a following dimension 12 does not update the slider once the zone has reported a setpoint in force. The slider follows dimension 12 (the setpoint the thermostat regulates to, knob offset included) as soon as the zone has reported it; a dimension 14 that is not the echo of a write from Home Assistant is kept as the commanded value only. Both captured plants (F461 2.0.11 with a KW4691, MyHomeServer1 3.87.13 with 36 zones) emit dimension 12 after every write and after every local change, so the slider stays current there; a gateway that echoed only dimension 14 for an external change would leave the slider on the previous value until the next dimension 12 report or poll. Reload the entity (homeassistant.update_entity) to poll *#4*Z##; please attach a trace if you see this.
Probes (WHERE ≥ 100) are read-only and push-driven. They NACK the explicit poll (*#4*ZPP*15##) and push readings on their own schedule. Nothing needed; a probe that goes silent is polled again after 5 min.

Burglar alarm (WHO 5)

Limitation Why Workaround
Zones are not individual entities; the panel follows the central unit (3485 / 3486). Some plants (F454 + 3486) emit zone status frames without exposing direct OpenWebNet arm / disarm commands (#311). OpenWebNet WHO 5 central units reject unauthenticated TCP arm/disarm writes by design; the integration models the central unit as a read-only panel (with optional WHO 9 AUX arm/disarm bridges) validated against physical 3486 and MH202 captures. Individual zone frames are available as myhome_message_event (with Generate Events on) and alarm state changes as myhome_alarm_event.
Arming requires the central unit to accept the command. Central units reject arming while a zone is open or the engineer code is active; the bus only reports the refusal. Watch the bus-monitor card for the NACK.

Door entry and intercom (WHO 6 / WHO 8)

Limitation Why Workaround
Gateways whose firmware routes no WHO 6 reject unlock commands (*6*10*<where>##) with NACK (*#*0##): MyHomeServer1, F455, F461, F450, F460, and the A/V gateways F454 / F459. (Discussion #833) MyHomeServer1, F450, F455, F460 and F461 ship no bt_vct door-entry translator, so they also see no WHO 6 / 8 traffic. F454 (and F459, which ships the same firmware image) routes only WHO 8 to bt_vct: it reports doorbells, but no program takes WHO 6. Either wire an MH-bus dry-contact relay actuator (F411/2, F411/1N, or F411/4 via interposing relays since F411/4 shares a common C terminal across its 4 channels) in parallel with the gate/strike dry-contact input and configure it as a WHO 1 impulse cover, or add a gateway that routes WHO 6 and sees the door-entry riser (MH200, MH202 or F453, with the riser reaching its bus, e.g. through an F422 interface) as a Shared Bus → Secondary gateway with WHO 6 (and WHO 8 for doorbells) delegated to it. F453AV ships bt_vct, but its WHO 6 routing is unverified.
HomeTouch 3488 indoor video displays neither bridge AV frames onto MH nor expose a local OpenWebNet server on TCP port 20000. (Discussion #833) HomeTouch 3488 has physically isolated MH SCS BUS and AV SCS BUS 2-wire terminals: tapping its screen for lights transmits on MH, while door/gate release buttons transmit strictly on AV. Over LAN, 3488 acts only as an OpenWebNet client pairing to MyHomeServer1 and exposes SIP/HTTPS for the BTicino cloud Door Entry for HOMETOUCH app — no local openserver listens on port 20000. Do not point the integration's host IP at HomeTouch 3488. Use an MH-bus dry-contact impulse relay (F411/2, F411/1N) at the gate/strike inputs or a WHO 6-capable gateway that sees the door-entry riser (see above).
Door entry locks (lock) are never auto-discovered from bus traffic. Creating a code-less lock entity automatically whenever someone presses an indoor door-release button would let anyone with dashboard access unlatch the strike. Declare door entry locks explicitly under lock: in myhome.yaml (with an optional code: PIN).

Sound system (WHO 16 / WHO 22)

Limitation Why Workaround
Streaming needs a network decoder per concurrent stream. With two decoders mapped, a third room asks for All audio matrix inputs are currently in use. The F441 matrix routes one physical input per source; the integration claims one decoder per playing zone. Map more decoders in the options flow, or group rooms on the decoder side.
Removing the group leader interrupts the music briefly. Unticking the leader in Music Assistant, or turning it off (Home Assistant or wall panel), stops the sound for a few seconds before the remaining rooms resume. Music Assistant owns one queue per player and can only move it by stopping it and starting a new stream on another player; a powered-off player cannot keep a queue. The bus itself is not interrupted: MyHOME switches only the leader's amplifier off and hands the decoder to the next room. See Why deselecting the group leader gives a short gap. Play to a Music Assistant Sync Group with Dynamic members on, so any room can be ticked and unticked; see Recommended: one Music Assistant Sync Group for the house. With temporary groups, play to a room that stays on: removing a member never interrupts anything.
Gateways that speak only WHO 22 (MyHomeServer1, F461) expose declared F500 / F500N FM tuners, not room amplifier zones. Those gateways ship bt_multi without bt_difson and reject every WHO 16 frame. F500 / F500N tuner sources (2#S / 5#2#S) are fully controlled and decoded over WHO 22, and dual-stack gateways also track WHO 22 area-source routing (4#<area>), whereas room amplifier discovery and zone power/volume/routing commands (01–99) require WHO 16. On a shared bus, pair a WHO 16-capable secondary gateway (such as MH200N, MH202, F454, H4890, or H/L4684 FW ≥ 6.0.0 for coupled WHO 16 / WHO 22, or MH200 for WHO 16) with audio delegated to it.

Scenario buttons (WHO 15 / 25)

Limitation Why Workaround
CEN / CEN+ devices are stateless. They have no entity, only device triggers. Pushbuttons report presses, holds, releases and rotary steps rather than a persistent on/off state. Use the device triggers (see CEN & CEN+) or the community blueprint.

Home Assistant integration surface

Limitation Why Workaround
entity_name in myhome.yaml only applies to sensors and binary sensors. On a light, switch, cover, thermostat, audio zone or alarm panel it is ignored: those entities are their device and carry the device name. Home Assistant's device / entity naming model; entity_name never named those platforms in earlier versions either. Rename the device in the UI, or change name.
Fresh installs name sensor ids after the device class (sensor.house_power, binary_sensor.cancello_opening) where earlier pre-releases produced sensor.house, sensor.house_2, binary_sensor.cancello. Earlier pre-releases used the device name with numeric suffixes for the second and third sensor of a device. Existing installations keep their ids; automations on a fresh install use the new ids.
Strict typing is complete. mypy --strict is enforced with zero errors across all integration modules (Platinum Quality Scale). —
myhome.yaml is a compatibility path, not the primary configuration. Devices are discovered from the bus; YAML only adds names, device classes and options. v2 is UI-first. Keep myhome.yaml for names and travel_time; delete devices you no longer want from the device page.
Deleting a device does not stop it from coming back. Devices are re-discovered from bus traffic; a device that still exists reappears on its next status frame. Only delete devices that are physically gone.
Home Assistant 2026.8 or newer is required (hacs.json). Current cores require Python 3.14 and modern via_device_id, repairs, and HTTP server APIs. Upgrade Home Assistant Core to 2026.8 or newer before installing MyHOME v2.0.