OpenWebNet Protocol Conformance & Capability Matrix¶
Authoritative Specification & Verification Baseline
Last Updated: November 17, 2026
Corpus Version: 2.0.0 (455 Fixtures, 21 Subsystems, 1,100+ Automated Conformance Assertions)
This document serves as the verifiable truth for OpenWebNet protocol conformance across the Home Assistant (OpenWebNet-HA/MyHOME) and Python protocol driver (OpenWebNet-HA/OWNd) ecosystem.
1. The Verification Authorities¶
To prevent divergence and eliminate guesswork, every protocol frame and capability is evaluated against four authorities:
| Authority | Reference Implementation | Role & Authority |
|---|---|---|
| 1. The Judge | Legrand OpenWebNet Official Specification Manuals (interrogated via openwebnet-mcp) |
Legal Grammar: Defines whether a frame syntax, dimension boundary, or parameter structure is strictly valid per Legrand standards. |
| 2. The Reference Oracle | openwebnet4j & openHAB OpenWebNet Binding (by Massimo Valla) |
Wire Baseline: Provides empirical on-wire factory strings, real-world edge cases, and 10+ years of mature production testing. |
| 3. The Firmware Oracle | own-firmware-oracle (tests/golden/firmware_oracle.json, 520 inputs across 12 emulated gateways) |
Hardware Truth: Provides hash-pinned gateway replies, SCS bus forwarding verdicts, and crash boundaries from real gateway binaries. |
| 4. The SUT | OWNd protocol engine & custom_components/myhome runtime |
System Under Test: Must parse, validate, roundtrip serialize, and build frames with 100% fidelity. |
2. Subsystem Conformance & Capability Matrix¶
| WHO | Subsystem | Verified Operations | Canonical Frame Examples | Judge (Legrand PDF) | Oracles & Captures | Runtime Status |
|---|---|---|---|---|---|---|
| - | Signaling | Gateway ACK / NACK | *#*1##, *#*0## |
Valid | Matched | VERIFIED (100%) |
| 0 | Scenarios | Activate, Stop, Execute, Programmer Lock/Unlock | *0*1*1##, *0*0*5##, *0*2*05##, *0*41*01## |
Valid | Matched + Live Captures | VERIFIED (100%) |
| 1 | Lighting | ON/OFF, Status, Speed Dimming, Private Bus (#4#01), DALI DT8 Tunable White, RGB/HSV |
*1*1*0311#4#01##, *1*1#5*12##, *#1*99*#1*150*0## |
Valid | Matched + Live Captures | VERIFIED (100%) |
| 2 | Automation | Shutter UP/DOWN/STOP, Bus Routing (#4#01), Go-to-level Position % (#11#PRIORITY) |
*2*1*21#4#01##, *#2*93*#11#001*75##, *2*2*93## |
Valid | Matched + Live Captures | VERIFIED (100%) |
| 3 | Load Control | Enabled priority states (#1..#8), Force priority (*3*2*#1##), priority status and CU measurement requests (Dims 0..4, probe-only) |
*3*1*#8##, *3*1*#1##, *3*2*#1##, *#3*10*0## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 4 | Thermoregulation | Probe queries (21.5°C), Setpoints, Knob offset (Dim 13), 0–10 V & Fan-coil (Dim 19/20), CU #0 |
*#4*1*0*0215##, *#4*88*13*13##, *#4*1#3*20*100##, *4*3100*#0## |
Valid | Matched + Live Captures | VERIFIED (100%) |
| 5 | Burglar Alarm | Zone/CU status, Intrusion & battery events, Empty/star-WHERE alarm status frames |
*5*1*0##, *#5*2##, *5*11*#2##, *5*1*## |
Valid | Matched + Live Captures | VERIFIED (100%) |
| 6 | Door Entry | Door lock release, Staircase light, Camera ON (probe-only), Free-channel short frames, Open lock in conversation | *6*10*4000##, *6*10*4003##, *6*9##, *6*22*1## |
Valid | Live Captures | VERIFIED (100%) |
| 7 | Multimedia | External camera video stream open and close (OWNAVCommand) |
*7*0*4000##, *7*9**## |
Valid | Legrand PDF only (no capture) | VERIFIED (100%) |
| 8 | Video Intercom | Internal/External audio-video calls, Pager broadcast and Status reads (probe-only), Entrance-panel calls, Caller-address report | *8*1#1#4#20*11##, *8*1#1#4*74##, *8*9#1#4*20##, *8*1#14#2#11*4## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 9 | Auxiliary | Relay ON/OFF indications and generic status queries across auxiliary channels | *9*1*4##, *9*0*4##, *#9*1## |
Valid | Matched + Live Captures | VERIFIED (100%) |
| 13 / 1013 | Gateway Mgmt | Time/Date/Timezone (999 & empty TZ), Firmware/Kernel/Distro, WHO 1013 object model |
*#13**0##, *#13**15##, *#13**#0*14*59*05*##, *#1013**1*67*15*5*0## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 14 | Actuator Lock | Point-to-point & #4#01 routed actuator lock (0) / unlock (1), General unlock event |
*14*0*11##, *14*0*07#4#01##, *14*1*0## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 15 | CEN Scenarios | Press, short release, long release, extended hold (#1/#2/#3), 4-digit source addresses |
*15*02*11##, *15*02#1*11##, *15*02#2*11##, *15*03#3*0512## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 16 | Sound System | Source ON/OFF, F441M matrix routing, Amplifier volume (Dim 1), RDS (Dim 8) |
*16*3*101##, *16*3*111##, *#16*23*1*15##, *#16*23*#1*15## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 17 | Scene Programmer | MH200N / MH202 scene start, stop, enable, disable & status requests | *17*1*30##, *17*2*30##, *17*3*30##, *#17*0## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 18 | Energy Mgmt | Active power (113 W), Cumulative/Monthly/Daily Energy (Wh) (51..54), Stream 1200, Stop & Go |
*#18*51*113##, *#18*51*51*8151646##, *#18*56*#1200#1*2##, *18*21*11## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 22 | Sound Diffusion | Multi-parameter speaker/source control, MH200N dual-frame mirror events, Volume/Preset/State | *22*1#4#1*3#1#1##, *22*2#4#1*5#2#2##, *#22*3#1#1*#1*17## |
Valid | Firmware Oracle + Capture | VERIFIED (100%) |
| 25 | CEN+ / Dry Contacts | Short press; start, hold and release of an extended press (2OBJECT); ScenarioPlus; dry contacts |
*25*21#1*21##, *25*22#1*21##, *25*12*131##, *25*31#1*339## |
Valid | Matched + Live Captures | VERIFIED (100%) |
| 1001 | Lighting Diag | Actuator autodiagnostic 24-bit (Dim 7 / Dim 11) bitmasks, Object model/FW/ID, Status request (probe-only) |
*#1001*0*7*111111111111111101101111##, *#1001*74*11*111110111111111111110111##, *#1001*0*2*1*3*8## |
Valid | Live Captures | VERIFIED (100%) |
| 1004 | Thermo Diag | Central/Probe/Zone 24-bit (Dim 7/11) & 16-bit (Dim 20/21/22) masks, Fault counters (23) |
*#1004*#0*7##, *#1004*66*11*111111111111111111111111##, *#1004*#66*22*1111111111111111##, *#1004*#0*23## |
Valid | Live Captures | VERIFIED (100%) |
A probe-only operation is a command or request that a contributor sent to an F461 (firmware 2.0.11) and that the gateway answered with NACK; no stored trace receives it. The matrix counts it as parsed and round-tripped by OWNd, not as a function confirmed on hardware. The fixture notes in tests/golden/frames/ name the trace behind each capture.
Sources for the examples changed in OWNd#77. The MyHomeServer1 firmware, run on an emulated bus, produces a bus frame for each of them and refuses the examples they replace. The WHO 15 press and short release (*15*01*73##, *15*01#1*73##) were captured on an MH200N + MyHomeServer1 bus in MyHOME#541. Long release and extended hold (#2, #3) are verified in both firmware and the four-digit 0512 capture in MyHOME#624. The WHO 25 examples are MH201 and H4890 captures from MyHOME#418 and MyHOME#466. The WHO 13 reads use the published empty-WHERE form *#13**DIMENSION## (Encyclopedia who-13-integration-gateway/dimensions.md "Read form"): in own-firmware-oracle (ownd-audit-frames and who13-clock) all emulated gateways answer *#13**0## and *#13**22## with ACK and the current time, while the WHERE 0 spelling *#13*0*0## is nack, silent; OWNGatewayCommand.request_time() and the event keepalive emit *#13**0##.
3. Key Architectural Truths & Design Decisions¶
3.1 String Preservation for Hardware Addresses¶
- Observation: Addresses such as
0311(Lighting PTP) and0110(CEN) begin with leading zeros. - Verifiable Truth: Addresses must never be converted to integers (
311or110). In OpenWebNet, leading zeros denote specific address spaces and module wiring. OWNd strictly enforces string types forwhereacross all subsystems.
3.2 Private Bus Routing (#4#bus)¶
- Observation: Installations with multiple physical SCS buses behind an F454 or 3486 gateway use interface routing (e.g.
*1*1*0311#4#01##). - Verifiable Truth: The interface routing suffix
#4#<interface>is an addressing qualifier, not a dimension parameter. OWNd extracts this cleanly intoparsed.interface = '01'andparsed.where = '0311', preserving 100% roundtrip wire string equality.
3.3 Strict Standards vs. Tolerant Synthesis (The Alarm WHERE Omission)¶
- Observation: In
openwebnet4j, frame*5*7*##(Alarm) synthesizesWHERE = '0'when the address is omitted, while gateways without a panel answer*#5*0##with*5*9*##. - Verifiable Truth: OWNd parses empty-
WHEREalarm status frames (*5*9*##) withwhere == ""so consumers never synthesize a phantom zone0device, while outbound command builders require an explicit address.
3.4 Extended Thermoregulation (Dimension 12 Setpoint After Local Offset)¶
- Observation: Dimension 12 is the complete probe status: its value is the zone's setpoint after the local offset, not a measured temperature (Encyclopedia
who-4-temperature-control/dimensions.md, "DIMENSION 12 - complete probe status":*#4*WHERE*12*T*3##,Tin0020..0430; measured temperatures are Dimension 0). The openwebnet4j fixture*#4*6*12*1048*3##carries a signed value the published range does not include. - Verifiable Truth: The value parameter
1048decodes as-4.8°Cwith theSXXXsign rule (the initial1indicates negative sign;048is tenths of a degree). OWNd stores it inlocal_set_temperature(message_typelocal_target_temperature);main_temperaturestaysNone.
4. Independent Local Verification¶
Any contributor or user can independently verify the conformance suite: