Welcome to the OpenWebNet Protocol & WHO Specifications Archive. This document serves as the official open-access registry and cross-check inventory of all technical manuals, frame syntax, dimension definitions, and PDF specifications published by BTicino / Legrand for the OpenWebNet protocol across MyHOME systems.

Historically, these technical specifications were distributed through the MyOpen Community portal (myopen-legrandgroup.com / myopen-bticino.it), which is no longer active. To ensure that developers, installers, and community members have permanent access to accurate protocol documentation, we maintain this centralized registry.


πŸ“‹ Community Cross-Check & Verification Status

Thanks to community contributionsβ€”in particular the comprehensive technical manual archive contributed by @GianlucaCh in PR #232β€”15 official specifications are now preserved, verified, and cross-checked against live installations!

If you are a certified BTicino / Legrand installer, system integrator, or MyHOME software specialist (such as @xtimmy86x, @lyubomirtraykov, and fellow community professionals), your real-world experience across varied plant configurations and engineering software continues to help us fill the final remaining gaps:

πŸ” Remaining Specifications & Items Under Review:

  1. Document Versions & Revision Dates:

    • Compare your PDF archive against the Master WHO Family Inventory table below.
    • Look at the cover page and revision history (e.g. Last date modify, Version number). If your copy is newer than what is listed, please share the version details!
  2. Remaining Missing / Legacy Specifications:

    • WHO = 3: Load control legacy central unit (F421) (Seeking newer official PDF than 2006).
    • WHO = 6: Dedicated audio door entry call frames (Seeking standalone document beyond WHO 7 / Intro).
    • WHO = 9: Auxiliary channels (AUX 1–9) (Seeking newer official PDF than 2006).
    • (Note: WHO = 14 Actuator Lock is fully reverse-engineered and documented below; Legrand never published a public standalone PDF).
  3. Software Tooling & Dictionaries (MyHOME_Suite / TiMyHome):

    • Command definitions or exported XML dictionaries from Legrand/BTicino configuration software (MyHOME_Suite, TiMyHome, Virtual Configurator, MyHOME_Up).

πŸ’‘ How to Contribute: You can share filenames, revision dates, technical sheets, or bus monitor traces by opening an issue on the OpenWebNet-HA/MyHOME GitHub repository or commenting directly in PR #232. Every contribution helps ensure open, permanent documentation for the entire MyHOME ecosystem.


πŸ“š Master WHO Family Inventory

The table below catalogs every known OpenWebNet function family (WHO), its official Legrand document title, current known version, archive status, and Home Assistant platform mapping.

Status Legend

  • 🟒 Archived & Verified: Official PDF is preserved in our archive with full syntax verified.
  • 🟑 Legacy Copy Available / Cross-Check Needed: Legacy documentation or reverse-engineered definitions exist; seeking confirmation of the latest official version.
  • πŸ”΄ Needed / Missing: Seeking the official Legrand/BTicino PDF specification.
WHO Subsystem / Function Official Document Title / Filename Known Version & Date Status Home Assistant Entity / Platform Notes & Supported Hardware
0 Scenarios (Basic) Open Web Net Language (Scenarios) / WHO_0.pdf v2.0.0 (2010-10-01) 🟒 β€” (myhome.send_message) 32 standard scenarios. Legrand 03551, 88301; BTicino F420, IR interface 3456. Contributed by GianlucaCh.
1 Lighting (Illuminazione) Who = 1 LIGHTING / WHO_1.pdf v1.1.0 (2014-11-17) 🟒 light, switch, cover, binary_sensor, sensor ON, OFF, Dimming (1-100%, 10 levels, steps), Blink, Timer, Speed of transition, impulse covers, motion/lux sensors. Extended lighting & DALI dimensions (tunable white / RGBW via F429/F429G). Contributed by GianlucaCh.
2 Automation (Automazione) Messages - Automation / WHO_2.pdf v1.0.0 (2015-11-12) 🟒 cover Roller shutters, venetian blinds (lift & slat tilt), motorized curtains, gates. Standard UP/DOWN/STOP and advanced absolute positioning percentage (0-100%, Legrand 67557). Contributed by GianlucaCh.
3 Load Control (Legacy) OpenWebNet_Community_3_LoadControl / WHO_3.pdf v1.0.0 (2006) 🟑 β€” (not implemented) Priority-based load disconnection central unit (F421). Inhibit/force actuators.
4 Thermoregulation (Termoregolazione) Open Web Net Language - Heating adjustment / WHO_4 2.pdf v2.0.0 (2013-11-27) 🟒 climate, sensor, switch 4-zone / 99-zone central units (4695, 3550), standalone thermostats (L/N/NT4691, Living Now), probe-less actuator relays, external probe sensors (3475). Supports dimension 0 (temperature), dimension 11 (fancoil 3-speed), dimension 12/14 (setpoints), dimension 13 (offset), dimension 15 (slave probes), dimension 20 (actuators), and dimension 60 (relative humidity). Contributed by GianlucaCh.
5 Burglar Alarm (Antifurto) MyHome Burglar Alarm / WHO_5.pdf (2008-02-13) 🟒 alarm_control_panel, myhome_alarm_event Central units (3485, 3486), read-only panel status and event bus notifications (arm/disarm via installer-programmed AUX frames). Authored by Lorenzo Pini. Contributed by GianlucaCh.
6 Door Entry Call & Lock OpenWebNet_Community_DoorEntry / WHO_6.pdf v1.0.0 (2006) 🟑 lock, myhome_doorbell_event Audio door entry calls, door lock release (*6*10*<WHERE>##), incoming call notifications.
7 Video Door Entry / Multimedia Open Web Net WHO=7 / WHO_7.pdf v1.0.1 (2011-12-01) 🟒 β€” (not implemented) Video session establishment, camera selection, video stream routing over IP for Video Server F453AV. Contributed by GianlucaCh.
8 Video Door Entry / Intercom Internal / Installer Spec (bt_vct) β€” 🟑 myhome_doorbell_event Entrance panel video doorbell notifications (*8*1#<1..4>#<mm>*<WHERE>##) on gateways connected to the door-entry riser (F454, F459, etc.).
9 Auxiliary (Comandi Ausiliari) OpenWebNet_Community_Auxiliary / WHO_9.pdf v1.0.0 (2006) 🟑 binary_sensor, switch Auxiliary channels (AUX 0 to AUX 9, declared in myhome.yaml) and per-device Invert state configuration switches.
13 Gateway Management OpenWebNet_Community_2_device_v1_0_0_EN / WHO_13.pdf v1.0.0 (2006-06-13) 🟒 β€” (Core diagnostics, myhome.sync_time) Date/time synchronization (*#13**#0*...), firmware version query, IP configuration, MAC address, device model probing. Contributed by GianlucaCh.
14 Actuators Lock (Light & Shutters) Light & Shutter Actuators Lock (No Public PDF) v1.0.0 (2008) 🟒 button Physical endpoint lock/unlock. Lock (*14*0*<WHERE>##), Unlock (*14*1*<WHERE>##), Status query (*#14*<WHERE>##). Disables/enables physical wall button input. Legrand never distributed a public standalone PDF (internal diagnostic spec).
15 CEN Scenario Control (Scheduler) CEN Frames for Scenario Scheduler / WHO_15-25.pdf v1.0.0 (2010-10-01) 🟒 myhome_cen_event, device triggers Pushbutton scenario events for Scenario Scheduler (MH200, MH200N, Legrand 03565): Virtual/physical pressure, short release, extended pressure, release after extended pressure. Contributed by GianlucaCh.
16 Sound Distribution (Zone/Amp Control) OpenWebNet_Community_4_soundsystem / WHO_16.pdf v1.0.1 (2011-11-24) 🟒 media_player, number, button Multi-room audio matrix & zone control: Amplifier ON/OFF, volume control (step & %), audio input source selection (RDS tuner, RCA/aux, network decoders), station presets (F441, F441M, F500, F500N, F450, 3487).
17 Scenario Programmer (Scenes) Who = 17 SCENES / WHO_17.pdf v1.0.0 (2015-04-09) 🟒 β€” (not implemented; myhome_scene_event only) MH200 / MH200N / MH202 scenario programmer lifecycle telemetry (myhome_scene_event on start/stop/enable/disable). Contributed by GianlucaCh.
18 Energy Management Functions Energy Management Functions / WHO_18 1.pdf v1.0.0 (2011-07-15) 🟒 sensor Instantaneous active power (W) and cumulative/daily/monthly active energy counters (Wh) in Home Assistant (F80/x, F520, F521, F522, F523, 3522; spec also defines V/mA/tariff dimensions). Contributed by GianlucaCh.
22 Sound Diffusion (Source & Speaker) Who = 22 Sound Diffusion / WHO_22.pdf v1.1.0 (2014-06-12) 🟒 media_player, number, button Sound source navigation & speaker control: Radio FM frequency step up/down, station navigation, track skipping (next/previous track), RDS text display control (*22*31...), station presets, active-source area notifications (4#<area>), and speaker volume (F500, F500N). Contributed by GianlucaCh.
24 Lighting Management (Gestione Luci) Who_24_eng_PUBBLIC.doc / WHO_24.pdf v1.0.0 (2012-04-06) 🟒 β€” (not implemented) Legrand / BTicino Lighting Management System (BMNE500 / 002645 room controller, BMview, Lighting Console). Zone addressing (1000+zone), dimensions 1–12, dimension 17 (Auto/Manual/Stop), dimension 18 (centralised lux reporting). Contributed by GianlucaCh.
25 (CEN+) CEN+ Scenario Control (Scheduler) CEN Frames for Scenario Scheduler / WHO_15-25.pdf v1.0.0 (2010-10-01) 🟒 myhome_cenplus_event, myhome_scenario_plus_event, device triggers Extended CEN+ protocol for MH200/MH200N/03565: Short pressure (<0.5s), start of extended pressure (>=0.5s), extended pressure holding, release after extended pressure, rotary dials, and Scenario Plus actions (WHAT = 11..15). Contributed by GianlucaCh.
25 (Contacts) Dry Contact & IR State Functions DRY CONTACT AND IR STATE FUNCTIONS / WHO_25.pdf v1.0.0 (2010-11-04) 🟒 binary_sensor, switch Dry contact interfaces & IR sensor state: State ON / IR detection (WHAT=31), State OFF / IR not detected (WHAT=32), plus per-device Invert state configuration switches. BTicino 3477, F428, 3480, F482, IR 4610/4611/4640; Legrand 573996, 03553, 067513, etc. Contributed by GianlucaCh.
HMAC Gateway Security & Authentication Hmac Specification / Hmac.pdf v1.1.0 (2016-08-05) 🟒 Core transport Cryptographic challenge-response HMAC-SHA256 authentication replacing legacy OPEN numeric password authentication for modern gateways (F454, F455, F461, MH202, MyHomeServer1). Contributed by GianlucaCh.
INTRO OpenWebNet System Architecture INTRODUCTION Examples of Integration / OWN INTRO.pdf (2012-10-03) 🟒 Core protocol Foundational architecture manual by BTicino detailing frame delimiters, session separation (Command vs Event/Status), ACK/NACK signaling, and system integration patterns. Contributed by GianlucaCh.
1000 Automation Group Commands Embedded in WHO 2 β€” 🟑 cover Area and General group broadcast commands for automation.
1001 Lighting Group Commands Embedded in WHO 1 β€” 🟑 light Area and General group broadcast commands for lighting.
1004 Temperature Group Commands Embedded in WHO 4 β€” 🟑 climate Zone group commands for thermoregulation.

πŸ“‘ Protocol Clarifications & Subsystem Distinctions

1. CEN/CEN+ Scenario Schedulers (WHO_15-25.pdf) vs Dry Contacts & IR (WHO_25.pdf)

A common source of confusion in the OpenWebNet ecosystem stems from the shared WHO = 25 code. As highlighted by @GianlucaCh, these are two completely distinct official specifications:

  1. Scenario Scheduler CEN / CEN+ (WHO_15-25.pdf):

    • Covered Devices: Scenario Programmers and Controllers (MH200, MH200N, MH201, Legrand 03565).
    • Protocol Nature: Pushbutton scenario trigger events.
    • Syntax: *25*<WHAT>*<WHERE>## where WHAT encodes:
      • 21: Short pressure (< 0.5 seconds).
      • 22: Start of extended pressure (>= 0.5 seconds).
      • 23: Extended pressure holding.
      • 24: Release after extended pressure.
    • Addressing (WHERE): Scenario address up to 256 buttons/scenarios ([1-256]).
  2. Dry Contact Interfaces & IR Sensors (WHO_25.pdf):

    • Covered Devices: Physical interface modules (BTicino 3477, F428, 3480, F482, IR 4610/4611/4640; Legrand 573996, 03553, 067513, etc.).
    • Protocol Nature: Hardware state telemetry for magnetic window/door reed switches, technical contacts, and passive infrared motion detectors.
    • Syntax: *25*<WHAT>*<WHERE>## or dimension frames where WHAT indicates:
      • 31: Contact ON / IR detection (closed contact or motion detected).
      • 32: Contact OFF / IR not detected (opened contact or motion cleared).
    • Parameter (PARAM):
      • PARAM = 0: State response upon polling request.
      • PARAM = 1: State response upon real-time system event.
    • Home Assistant Entity: Exposed as binary_sensor (e.g. window opened/closed, PIR motion).

2. Multi-Room Sound System (WHO = 16) vs Sound Diffusion (WHO = 22)

WHO = 16 and WHO = 22 are two distinct OpenWebNet audio dialects encoding overlapping concepts with different commands, addresses, and dimensions:

  1. WHO = 16 (Sound System β€” Amplifiers, Matrix Routing & Sources):

    • Original BTicino sound-system dialect (WHO_16.pdf v1.0.1, bt_difson gateway daemon) covering both room amplifiers (01–99), F441/F441M environment matrix routing (1ES), and audio source / F500 / F500N FM tuner devices (101–109).
    • Functions include: Zone power (WHAT = 0/3/10/13), volume (0–31 scale), environment-to-source routing (*16*3*1ES##), tone equalizers, FM tuner frequency (*#16*10S*#6*0*<KHZ>##), presets (*#16*10S*#7/<station>##, *#16*10S*#10*<slot>##), seek, and RDS (*#16*10S*8*...##).
    • Mapped in Home Assistant to zone media_player entities (plus dynamic streaming proxy) and tuner media_player / number / button entities.
  2. WHO = 22 (Sound Diffusion / Multimedia β€” Structured Later Dialect):

    • Later multimedia dialect (WHO_22.pdf v1.1.0, bt_multi gateway daemon) using tagged addresses for sources (2#<S> / 5#2#<S>), speakers (3#<A>#<P>), and speaker areas (4#<A>). Dual-stack gateways (MH200N, MH202, F454, H4890, H/L4684 FW β‰₯ 6.0.0) emit both dialects; newer gateways (MyHomeServer1, F459, F460, F461) ship bt_multi (WHO = 22) only.
    • Functions include:
      • FM tuner frequency search/tune (WHAT = 5 / WHAT = 6), station preset navigation (WHAT = 9 / WHAT = 10), preset storage (WHAT = 33), frequency/station telemetry (Dimension 5 / 6 / 11), and RDS text (WHAT = 31 / 32, Dimension 10).
      • Active-source area notifications (WHAT = 1/2/21/23#4#<area>) and speaker volume/tone controls (WHAT = 3 / 4, Dimension 1–4).
    • In Home Assistant, declared F500 / F500N FM tuners (media_player, number, button) are controlled and decoded across both WHO = 16 and WHO = 22 (including WHO = 22-only gateways), and dual-stack gateways also track WHO = 22 active-source area routing (4#<area>) alongside WHO = 16 room amplifier zones.

3. Actuator Diagnostics & Endpoint Safety Locks (WHO = 14)

BTicino and Legrand never distributed a standalone WHO_14.pdf in their public developer distributions, retaining it as an internal/installer diagnostic function. However, the protocol grammar is fully reverse-engineered and verified across live systems:

  • Protocol Function: Inhibits physical wall buttons (rocker switches, CEN pushbuttons) and remote actuation for safety, maintenance, or child locking on lighting and cover/shutter actuators (F411, F411U2, F418, LN4672M2).
  • Lock Actuator (Disable Controls): *14*0*<WHERE>##
    • Freezes the relay in its current position and disables physical switch inputs.
  • Unlock Actuator (Enable Controls): *14*1*<WHERE>##
    • Restores normal operation and re-enables physical wall buttons and bus commands.
  • Status Query: *#14*<WHERE>##
    • Returns *14*0*<WHERE>## (Locked) or *14*1*<WHERE>## (Unlocked).
  • Home Assistant Integration: Represented via configuration button entities (DisableCommandButtonEntity and EnableCommandButtonEntity) under each actuator device.
  • Gateway Support: Supported on modern gateways (F454, MyHomeServer1). Older gateways (e.g. early F455 firmware) return NACK (*#*0##).

πŸͺ„ CEN / CEN+ Automation & Community Blueprints

One of the most powerful capabilities of physical MyHOME installations is using existing BTicino wall pushbuttons and dry contact modules (such as the 3477 interface) to trigger automations across modern smart home ecosystems.

🌟 Community Blueprint: MyHome CEN+ Commands

A highly recommended blueprint developed by the Home Assistant community (by gST84) is available on the Home Assistant Community Forum:

πŸ‘‰ MyHome - CEN+ commands Blueprint (Community Forum)
πŸ‘‰ Raw Blueprint Source YAML (GitHub)

Key Features of the Blueprint:

  1. Control Non-BTicino Devices: Use your native BTicino wall switches to switch or toggle non-BTicino smart devices (Philips Hue, Zigbee, Z-Wave, Shelly, or Tuya).
  2. Short vs. Long Press Handling:
    • Short Press (< 0.5s): Instantly toggles lights or triggers scenes.
    • Extended / Long Press (>= 0.5s): Enables smooth dimming up or down.
  3. Dimming Direction Helper:
    • By creating a simple input_boolean helper (e.g. input_boolean.living_dim_direction), the blueprint tracks dimming direction so alternating long presses cycle between brightening and dimming.
  4. Zero-Delay Bus Processing: Fully compatible with the stateless myhome_cen_event and myhome_cenplus_event events dispatched by the modernized MyHOME integration.

πŸ”Œ Gateway Architecture & Hardware Profiles

The table below outlines supported hardware gateways, session concurrency, inter-frame pacing requirements, and authentication mechanisms (automatically synchronized with OWNd profiles):

Gateway Model Protocol Support Max Command Workers Inter-Frame Delay UPnP Discovery Notes
F454 OpenWebNet / HMAC 4 workers 50 ms βœ… Port 49153 Full high-speed multi-session support
F455 OpenWebNet / HMAC 4 workers 50 ms βœ… Port 49153 Basic gateway (single SCS bus)
F461 OpenWebNet / HMAC 4 workers 50 ms ❌ Manual Compact DIN Ethernet Web Server
MH202 OpenWebNet / HMAC 2 workers 100 ms βœ… Port 49153 Modern scenario programmer gateway
MH201 OpenWebNet 1 worker 100 ms βœ… Port 49153 Second-generation scenario programmer
MyHomeServer1 OpenWebNet / HMAC 4 workers 20 ms βœ… SSDP Cloud/local hybrid gateway
MH200N OpenWebNet 1 worker 150 ms βœ… SSDP Second-generation scenario programmer
MH200 (Legacy) OpenWebNet 1 worker 150 ms βœ… SSDP Strict single-session pacing; watchdog hardened
H4890 / AM4890 OpenWebNet 1 worker 50 ms βœ… SSDP 3.5" Touch screen display IP gateway (Axolute / Livinglight)
F452 / F453 / F453AV OpenWebNet 1 worker 150 ms βœ… Port 49153 Audio/video & web server gateway
H4684 / H/L4684 OpenWebNet 1 worker 50 ms βœ… SSDP Colour touch screen IP gateway (Axolute / LivingLight)

πŸ” OpenWebNet Frame Syntax Quick Reference

OpenWebNet messages always begin with * and end with ##. Fields are separated by *:

  1. Standard Command / Status Message:

    *WHO*WHAT*WHERE##
    
    Example: *1*1*21## (Turn ON light at address A=2, PL=1)

  2. Dimension Request (Query):

    *#WHO*WHERE*DIMENSION##
    
    Examples:

    • *#4*1*0## (Query measured temperature of Zone 1)
    • *#4*1*60## (Query relative humidity of Zone 1)
  3. Dimension Writing (Command with Parameters):

    *#WHO*WHERE*#DIMENSION*VAL1*VAL2*...*VALn##
    
    Example: *#16*1*#1*30## (Set volume of audio Amplifier 1 to step 30 of 31, ~97%)

  4. Dimension Response (Status Report):

    *#WHO*WHERE*DIMENSION*VAL1*VAL2*...*VALn##
    
    Examples:

    • *#4*1*0*0215*1## (Zone 1 temperature is 21.5 Β°C, Heating mode)
    • *#4*1*60*55## (Zone 1 relative humidity is 55%)
  5. Acknowledge (ACK / NACK):

    • *#*1## : ACK (Command accepted by gateway/bus)
    • *#*0## : NACK (Command rejected, syntax error, or buffer busy)

πŸ› οΈ Testing & Live Bus Capture in Home Assistant

To capture raw OpenWebNet frames from physical hardware or diagnostic sessions:

  1. Add the Lovelace Bus Monitor Card to your dashboard:
    type: custom:myhome-openwebnet-bus-monitor
    # Note: custom:myhome-bus-card is also supported as an alias
    
  2. Operate your devices (e.g. adjust a DALI color ballast, toggle a dry contact switch, or change audio volume).