Sensors & Energy (WHO = 18, WHO = 4, WHO = 1)

The MyHOME integration provides monitoring for electrical energy meters, ambient temperature probes, and light sensors across OpenWebNet WHO = 18, WHO = 4, and WHO = 1.

In v2, setup and management are 100% UI-first: sensors are automatically discovered from bus telemetry without manual YAML configuration files.


⚡ Power & Energy Meters (WHO = 18)

The integration natively interfaces with Legrand / BTicino DIN power management actuators:

  • BTicino F520: Single-phase power and energy meter (WHERE = 51 through 5255).
  • BTicino F522 / F523: Multi-circuit energy and power management modules (WHERE = 71 through 7255).

Auto-Discovered Entities

When an energy meter is detected on the SCS bus, the integration creates entities only for the measurements the meter actually reports:

  1. Instantaneous Power Sensor (device_class: power): Real-time active power consumption in Watts (W).
  2. Total Energy Counter (device_class: energy, state_class: total_increasing): Cumulative electrical energy consumption in Watt-hours (Wh).
  3. Periodic Energy Counters: Daily and monthly energy sub-counters (created disabled by default in the entity registry; enable them in Home Assistant if needed).

Home Assistant Energy Dashboard Integration

Because energy entities implement standard state_class: total_increasing and device_class: energy:

  1. Navigate to Settings → Dashboards → Energy.
  2. Under Electricity Grid → Add Consumption, select your discovered MyHOME total energy sensor (e.g. sensor.total_power_energy).
  3. Home Assistant automatically generates hourly, daily, and monthly solar/grid tracking graphs.

Live High-Frequency Power Streaming

To instruct a power meter to stream high-frequency instantaneous power updates (Dimension 113) to Home Assistant, call myhome.start_sending_instant_power targeting the power sensor entity (optional duration: 1–255 minutes, default 65), and call myhome.stop_sending_instant_power to stop streaming early:

action: myhome.start_sending_instant_power
target:
  entity_id: sensor.general_power
data:
  duration: 65   # Optional: 1–255 minutes (default: 65)
action: myhome.stop_sending_instant_power
target:
  entity_id: sensor.general_power

Tip

Projecting Smart Meters or Solar Inverters onto the SCS Bus: To publish non-MyHOME power and energy measurements (such as Shelly EM, SolarEdge, Enphase, or utility smart meters) onto SCS meter addresses for display on wall touchscreens, see the Expose to Bus Guide.


🌡️ Temperature Sensors (WHO = 4)

Standalone and secondary temperature probes operating on WHO = 4 are automatically discovered as sensor entities with device_class: temperature:

  • Standalone & Secondary Probes (WHERE ≥ 100, i.e. 0101–0999 / 101–899, or Dimension 15): Auto-discovered from SCS bus traffic (including battery-powered wireless probes such as BTicino 3455 behind L4577 radio interfaces, and outdoor/slave probes 3475/3476).
  • Thermostat Zones (WHERE = 1..99): Zone addresses 1..99 belong to climate.* thermostat entities by default and do not spawn duplicate standalone temperature sensor entities unless explicitly declared under sensor: in /config/myhome.yaml.

☀️ Illuminance Lux Sensors (WHO = 1)

Light intensity sensors (e.g. Legrand 048822 ceiling detectors configured in scenario mode) operating on WHO 1 report ambient lux levels:

  • Entity: sensor.<name>_illuminance
  • Device Class: illuminance (unit: lx)
  • Use Case: Drive automated curtain/blind closing when solar glare exceeds threshold, or trigger dusk lighting.
  • Address: a WHO 1 point address; an area-0 point with PL 1..9 is spelled in two digits (04), so where: "0004" in myhome.yaml is resolved to 04 and a …-1-0004-illuminance entity is moved to …-1-04-illuminance at startup (#147).

🔄 Legacy YAML Note

Note

WHO = 18 energy meters, WHO = 4 standalone probes (WHERE ≥ 100 or Dimension 15), and WHO = 1 illuminance sensors are discovered dynamically from the bus; sensor: entries in /config/myhome.yaml remain supported for custom naming or exposing thermostat zone (1..99) temperatures as standalone sensor entities. For migrating pre-v0.9 configuration.yaml files, see the Legacy YAML Migration Guide.