Skip to content

Hardware Compatibility Matrix

The MyHOME integration supports all official BTicino and Legrand OpenWebNet gateways communicating via TCP/IP sockets or USB/Serial interfaces.


Supported Gateways

Gateway Model Manufacturer Connection Type Port / Baud Max Sockets HMAC / SHA Auth Recommended Profile
MyHomeServer1 BTicino Ethernet (IP) 20000 4 Yes (required) MyHomeServer1Profile
F454 BTicino / Legrand Ethernet (IP) 20000 2–3 Optional F454Profile
F455 BTicino Ethernet (IP) 20000 2–3 Optional F455Profile
MH200N BTicino Ethernet (IP) 20000 1 No MH200NProfile
MH201 BTicino Ethernet (IP) 20000 1 No MH201Profile
MH202 BTicino Ethernet (IP) 20000 1 No MH202Profile
F452 / F452V BTicino Ethernet (IP) 20000 1 No F452Profile
MHServer / MHServer2 BTicino Ethernet (IP) 20000 1 No MHServerProfile
F461 BTicino Ethernet (IP) 20000 2 No F461Profile
Legrand 3578 Legrand USB / RS232 Serial 57600 1 N/A SerialProfile

Note

Gateways with only 1 concurrent command session (such as the MH200N or MH201) are automatically tuned with command pacing (150 ms) to avoid queue flooding. Modern multi-session gateways (F454, MyHomeServer1) use 20 ms pacing with worker pools.


Supported Bus Subsystems (WHO)

Subsystem WHO Code Home Assistant Platform Typical Hardware Modules
Lighting 1 light, switch F411/1, F411/2, F411/4, F418 (dimmer), F429 (DALI), 3560, L4652
Automation / Covers 2 cover F401, F411, LN4672M2, 67557
Thermoregulation 4 climate, sensor 3550, 4695 (Central Units), 3455, L4691, L4577, F430/2, F430/4
Burglar Alarm 5 alarm_control_panel 3485, 3486 (Central Units), 3480
Gateway Diagnostics 13 diagnostics, repair Gateway internal RTC clock, firmware, uptime, device types
Scenario Control (CEN) 15 device_trigger, event 3477, L4651/2, L4652/2 (Short / Long press)
Sound System 16 media_player F441, F441M (Audio matrix), 3445 (amplifiers), 3482
Energy Management 18 sensor F520, F521, F522, F523, 3522
Scenario Control (CEN+) 25 device_trigger, event L4652/3, LN4652, H4652 (Rotary dials, pushbuttons)