MyHOME for Home Assistant โ Project Roadmap & Architectural Status¶
Welcome to the development roadmap and architectural status overview for the MyHOME for Home Assistant integration.
Our overarching mission is to provide the most reliable, complete, and high-performance integration between Home Assistant and the BTicino / Legrand SCS OpenWebNet ecosystem. We adhere to strict standards: zero-latency asynchronous architecture, hardware-level protocol fidelity, 100% automated test coverage, and full Home Assistant Core 2025/2026 compatibility.
Tip
For release-by-release changelogs, download assets, and direct GitHub compare links across published versions, see GitHub Releases.
๐บ๏ธ Current Delivery Status (v2.0.0 Stable Release Ready)¶
The major architectural milestones originally planned across Phases 1 through 4 have been consolidated, fully implemented, and validated with 100% statement and branch test coverage for v2.0.0 on OWNd==2.0.1.
gantt
title MyHOME Integration Status & Roadmap
dateFormat YYYY-MM-DD
section Delivered in Phase 1 & 2 (b1 โ b8)
Async TCP Transport & Core Architecture (P1) :done, 2026-08-01, 2026-09-01
Lovelace In-Band Bus Monitor Card (<myhome-bus-card>) :done, 2026-08-15, 2026-09-10
Standalone OWNd Library & Master WHO Catalog :done, 2026-09-01, 2026-09-10
section Delivered in Phase 3 & 4 (b9 โ b13)
Command Translation (WHAT=1000) Frame Filtering :done, 2026-09-10, 2026-09-11
CEN/CEN+ UI Device Triggers & Pruning Exemption :done, 2026-09-10, 2026-09-11
DALI HSV Color (Dim 12) & Tunable White (Dim 14) :done, 2026-09-10, 2026-09-11
Central Unit Coordination 3550 / 4695 :done, 2026-09-10, 2026-09-11
Hardware Gateway Profiles (F454, MHS1, MH200) :done, 2026-09-10, 2026-09-11
Deterministic Plant Trace Replay Engine (P5) :done, 2026-09-10, 2026-09-11
Engine Upgrade: OWNd 2.0.0b8 (HMAC SHA-1/SHA-256) :done, 2026-09-12, 2026-09-18
Climate Fan Mode Persistence (#404) :done, 2026-09-15, 2026-09-18
Home Assistant Platinum Quality Scale Alignment :done, 2026-09-15, 2026-09-18
section Released in v2.0.0b14 (2026-09-30)
Multi-Gateway Plant Isolation Architecture (#453) :done, 2026-09-19, 2026-09-24
Climate Zone HVAC Action & State Diagnostics (#457) :done, 2026-09-20, 2026-09-25
F500 FM Tuner Dimension Reports & RDS Decoding :done, 2026-09-21, 2026-09-26
Touchscreen Profiles (AM4890, H4890, LN4890) :done, 2026-09-22, 2026-09-27
F520 Proactive Energy Meter Bus Sweeps (#494) :done, 2026-09-24, 2026-09-30
section Released in v2.0.0b15 (2026-10-07)
CEN/CEN+ Trigger Isolation (#601) & Phantom Illuminance Fix (#604) :done, 2026-10-01, 2026-10-02
Read-Only Alarm Panel with AUX Arm/Disarm (#564) :done, 2026-10-01, 2026-10-03
Device Fault Repairs (#593) & Blank-Start Discovery (#578) :done, 2026-10-01, 2026-10-03
Ignored Addresses Option (#611) & Dimmer No-Load WHAT 19 (#619) :done, 2026-10-03, 2026-10-04
Firmware-Aware Gateway Profiles (OWNd#80) :done, 2026-10-04, 2026-10-05
section Released in v2.0.0b16
WHO 4 Seasons, Holiday Programs & Humidity (#657, #689, #712) :done, 2026-10-08, 2026-10-14
WHO 22 Tuner RDS (#695) & WHO 25 Scenario Plus (#671) :done, 2026-10-08, 2026-10-16
Cover Start-Up Floor & Full Runs (#702, #707, #708) :done, 2026-10-08, 2026-10-17
Venetian Blind Slat Tilt (#492, #508) :done, 2026-09-23, 2026-10-18
Impulse Gate & Garage Covers, Intercom Events (#667) :done, 2026-10-08, 2026-10-19
Expose HA Entities to the Bus (#750) :done, 2026-10-14, 2026-10-21
section Released in v2.0.0b17
Cover End-Stop Settle (#834, #847) & Min Delta (#778) :done, 2026-10-22, 2026-11-04
Central Unit 3550 Hydration & Actuator Switch (#817, #846) :done, 2026-10-25, 2026-11-04
OWNd 2.0.0b13 Pin & Legrand 067292 Alias (#848, #854) :done, 2026-10-26, 2026-11-04
F500 FM Tuner Controls & Station Range Bounds (#839, #844) :done, 2026-10-28, 2026-11-04
Dimmer Preset Echo & Coarse Curve Alignment (#828, #852) :done, 2026-10-28, 2026-11-04
section Released in v2.0.0b18
Live Cover Animation (~1 s) & Venetian Tilt on Dim 10 Stops (#870, #900) :done, 2026-11-05, 2026-11-14
WHO 4 Startup Pacing, Offset Reads & 3100 Auto (#887, #902, #909) :done, 2026-11-05, 2026-11-14
Expose Virtual Dimmer Hold-Up & Firmware Gates (#883, #904) :done, 2026-11-09, 2026-11-14
OWNd 2.0.0b14 Pin & BTicino F453 Identity (#901, #909) :done, 2026-11-13, 2026-11-14
section Delivered in v2.0.0
RestoreSensor kWh Fix, Dim 19/20 Idle & N4692 Knob (#913, #914, #921) :done, 2026-11-14, 2026-11-15
Marketplace 2026.11, Apache-2.0 Docs & Golden Corpus (#906, #922, #923) :done, 2026-11-14, 2026-11-15
Dim 10 Auto-Detect, Silent-Zone Poll, Motion Timer & OWNd 2.0.1 (#927, #931, #933, #935, #938โ#940, #942) :done, 2026-11-16, 2026-11-17
section Final Stabilization
v2.0.0 Release Stabilization :done, 2026-10-05, 2026-11-17
๐ฆ What is Shipped & Operational in the v2.0.0 Series¶
The following table summarizes the completed architectural features and protocol subsystems verified for the v2.0.0 release:
| Priority / Feature | Subsystem | Implementation Status | Highlights |
|---|---|---|---|
| Standalone Protocol Engine (P1) | Core | โ
Shipped (OWNd==2.0.1) |
Fully decoupled, strongly typed async engine on PyPI; supports legacy clear-text, numeric, and modern HMAC-SHA1 / HMAC-SHA256 session handshakes plus firmware-aware gateway profiles. |
| Expose HA Entities to the Bus | Core / WHO=1, 2, 4, 13, 18 | โ Shipped (#750, #883, #904) | Declarative expose engine: virtual WHO 1 / WHO 2 actuators, firmware-gated WHO 4 / WHO 18 virtual probes, and the WHO 13 bus clock. |
| Multi-Gateway Isolation Architecture | Core / Routing | โ Shipped (#453) | Namespaced dispatchers, independent session queues, and cross-gateway bus protection eliminating cross-talk in multi-gateway installations. |
| CEN / CEN+ UI Device Triggers (P2) | WHO=15 / 25 | โ Shipped | Native Home Assistant UI device triggers with preserved 4-digit addressing ("0001"), parent gateway isolation, and all 8 press/held/release actions with repeat debouncing. |
| In-Place Gateway Reconfiguration | Config / Options | โ Shipped | Update IP address (host), port, or password via Reconfigure, and change hardware model or runtime options via Configure (Options Flow) without deleting devices or breaking entity IDs. |
| Dynamic Command Worker Concurrency | Transports | โ Shipped | User-configurable (1โ4 workers) command concurrency automatically capped to hardware-safe limits per gateway model (e.g. 1 for MH200/MH201, 4 for F454/MHS1). |
| Native Hardware Bus Timers | WHO=1 | โ Shipped | Offloaded countdown timers on Legrand DIN actuators (F411) via the dedicated myhome.turn_on_timed service action (0.5โ918,000 seconds). |
| Central Unit Coordination (P4) | WHO=4 | โ Shipped (#817, #846, #909) | Dedicated master coordination for 99-zone Central Unit (#0, model 3550, including *4*3100*#0## auto restore) and 4-zone Central Unit (#0#1, model 4695). Master Seasonal switches propagate to subordinate zones. |
| Climate Zone State Diagnostics | WHO=4 | โ Shipped (#404, #457, #908, #914, #921, #933, #940) | Dynamic HVAC action deduction (heating, cooling, idle incl. Dimension 19/20 codes 14..16 & 100 and multi-actuator F455 Dimension 19 status), Dimension 11 / 20 fancoils, Dimension 13 knob detents, fan mode persistence across restarts, and paced startup/silent-zone sweeps. |
| Real-World CI Trace Replay Engine (P5) | Testing / CI | โ Shipped | Automated pytest fixture engine (tests/test_trace_replay.py) replaying authentic on-wire captures across 12 physical gateway families directly against Home Assistant state machines. |
| DALI Tunable White & Color | WHO=1 | โ Shipped | DALI DT8 tunable white (Kelvin 2000Kโ6535K / mireds, Dimension 14), native HSV color promotion (Dimension 12), and smooth dimming speed curves. |
| Declared Groups & Assumed State | WHO=1 | โ Shipped (#368, #376, #377) | Lighting groups declared under light: (where: '#G', optional members:) with aggregate/assumed-state inference and 500 ms debounced targeted status sweeps (broadcast_resync) upon intercepting group (WHERE=#1), area, or general (WHERE=0) frames. |
| Cover Live Animation, Venetian Tilt & Travel Calibration | WHO=2 | โ Shipped (#433, #870, #900) | ~1 s interpolated live travel-time positioning, Dimension 10 / 11 position feedback, Venetian slat-tilt tracking across intermediate Dimension 10 stops, dedicated cover run-stop locks, and on-bus stopwatch calibration (myhome.calibrate_cover, Calibrate travel time, and Calibrate all covers). |
| Sound System 2.0, WHO 22 RDS Tuners & Streaming Proxy | WHO=16 / 22 | โ Shipped (#695, #839, #844) | Multi-room matrix amplifier control (F441/F441M over WHO = 16), F500/F500N FM RDS tuner controls (media_player, number, button) on both WHO = 22-only (MyHomeServer1, F461) and dual-stack gateways, 4#<area> active-source area tracking, and Dynamic Proxy Decoders for Music Assistant / Spotify. |
| Door Entry Locks & Intercom Events | WHO=6 / 8 | โ Shipped (#667) | Door lock release entities (lock.py, configurable hold pulse and optional PIN confirmation) and video intercom call event triggers. |
| Energy Management & Metering | WHO=18 | โ Shipped (#494, #907, #913) | Instantaneous active power (W), unit-safe RestoreSensor cumulative total/daily/monthly Wh/kWh counters, and proactive bus sweeps for F520 / F521 / 3522 DIN meters. |
| Burglar Alarm | WHO=5 | โ Shipped (#564) | Armed / disarmed / triggered state (read-only panel), zone 0 synchronization, myhome_alarm_event notifications, and optional AUX (WHO = 9) arming/disarming bridge for central units (3485/3486). |
| Dry Contacts & Technical Alarms | WHO=25 | โ Shipped | Dynamic discovery, device class suffix stripping (#247), inverted contact states, and event dispatching for Legrand 3477 binary sensors. |
| Lovelace Bus Monitor Card | Frontend | โ
Shipped (<myhome-openwebnet-bus-monitor>) |
Live scrolling stream, color-coded WHO badges, scoped custom element registry self-healing (#277), syntax injector, ๐ด Start Trace / โน Stop Trace recording, and ๐ Copy Trace / ๐พ Export Trace export. |
๐ Integration Quality Scale (IQS) Alignment¶
MyHOME is engineered to achieve the official Home Assistant ๐ฅ Platinum Quality Seal (Home Assistant Integration Quality Scale) for potential Core inclusion, ensuring the highest architectural standards regardless of distribution model.
Note
Community Consultation on Upstream Core Inclusion vs. Independent Distribution:
While the integration strictly adheres to 100% of Home Assistant Core Platinum standards, the maintainers and community have not decided on upstream Core inclusion. As discussed in community channels (see RFC Discussion #248), there are important trade-offs:
- Benefits of Core inclusion: Automatic out-of-the-box discovery for new Home Assistant users without requiring Marketplace / HACS installation; official documentation on
home-assistant.io. - Drawbacks & Advantages of remaining an independent custom component:
- Release Agility: Rapid deployment of bugfixes, firmware quirk workarounds, and new WHO dimension features without waiting for monthly Home Assistant Core release windows.
- Dedicated Diagnostic Frontend: Continued bundling and rapid iteration of the in-band
<myhome-bus-card>Lovelace tool and live bus monitors, which are constrained within Core repository guidelines. - Community Traces & Plant Fixtures: Fast, unencumbered additions of real-world captures and experimental protocol options.
Feedback from installers and users is actively welcomed in our Discussions.
All 54 quality scale rules are tracked in custom_components/myhome/quality_scale.yaml and continuously validated by scripts/verify_ha_standards.py:
graph LR
subgraph Bronze["๐ฅ Bronze Tier (100% Satisfied)"]
B1["has_entity_name = True"]
B2["entry.runtime_data Mapping"]
B3["async_setup Action Registration"]
B4["Config Entry Unique IDs"]
end
subgraph Silver["๐ฅ Silver Tier (100% Satisfied)"]
S1["100.0% Strict Test Coverage"]
S2["ServiceValidationError Handlers"]
S3["PARALLEL_UPDATES = 0 Declarations"]
S4["No Blocking Event Loop Calls"]
end
subgraph Gold["๐ฅ Gold Tier (100% Satisfied)"]
G1["async_step_reconfigure"]
G2["strings.json & en.json Translations"]
G3["icons.json Translatable Icons"]
G4["Home Assistant Repairs Framework"]
G5["diagnostics.py Platform"]
end
subgraph Platinum["๐ Platinum Tier (100% Satisfied)"]
P1["Async Client Library (OWNd)"]
P2["Zero HA Imports in Client Engine"]
P3["Strict Anti-Drift Sentinels"]
end
Bronze --> Silver --> Gold --> Platinum
๐ Quality Scale Audit Highlights¶
-
Bronze Tier:
has-entity-name: All entity implementations inherit device names cleanly without manualself.entity_idoverrides.runtime-data: 100% single-source access viaentry.runtime_data(MyHOMERuntimeData); zero legacyhass.data[DOMAIN]global lookups.action-setup: Service actions registered once inasync_setupand preserved across individual entry reloads.
-
Silver Tier:
test-coverage: Enforced strict 100.0% statement coverage across all integration modules (verified bytests/test_coverage_enforcer.pyandscripts/verify_ownd_coverage.py).parallel-updates: ExplicitPARALLEL_UPDATES = 0declared across all 11 platform files to guarantee event-driven thread safety.
-
Gold Tier:
reconfiguration-flow: In-place gateway IP address (host),port, andpasswordupdates via Reconfigure, with hardwaremodeland runtime options configurable via Configure (Options Flow).repair-issues: Built-in repairs platform (repairs.py) raising user-actionable diagnostics (e.g. unconfigured gateway timezone sentinel999, unknown gateway model999, model conflicts, device faults).diagnostics: Comprehensive diagnostics export with automatic redaction of passwords and tokens.
-
Platinum Tier:
async-dependency: Zero blocking network calls; standalone asynchronous client engine (OWNd==2.0.1) on PyPI.clean-separation: OWNd engine imports zero Home Assistant symbols and runs independently on Linux/Windows/macOS.
๐ Real-World Trace Coverage Schematic (What We Have vs. What We Need)¶
To eliminate regression risks and verify complex timing constraints, our Trace Replay Engine (tests/test_trace_replay.py) replays authentic on-wire captures against the Home Assistant integration.
Below is the live, automatically synchronized status of real-world captures in CI, and remaining niche plant scenarios where community traces are welcomed:
๐บ๏ธ System Coverage Overview¶
graph TD
subgraph Gateways["๐๏ธ Gateways & Transports"]
GW_MHS1["๐ข MyHomeServer1<br/>(47 captures ยท 6,879 rx)"]
GW_F454["๐ข F454<br/>(23 captures ยท 4,447 rx)"]
GW_F455["๐ข F455<br/>(10 captures ยท 565 rx)"]
GW_F459["๐ข F459<br/>(1 capture ยท 898 rx)"]
GW_F461["๐ข F461<br/>(19 captures ยท 2,872 rx)"]
GW_MH202["๐ข MH202<br/>(9 captures ยท 672 rx)"]
GW_MH201["๐ข MH201<br/>(9 captures ยท 970 rx)"]
GW_MH200N["๐ข MH200N<br/>(16 captures ยท 1,664 rx)"]
GW_MH200["๐ข MH200<br/>(12 captures ยท 1,332 rx)"]
GW_F453["๐ข F452 / F453 / F453AV<br/>(10 captures ยท 1,065 rx)"]
GW_H4890["๐ข H4890 / AM4890 / 067292<br/>(5 captures ยท 983 rx)"]
GW_H4684["๐ข H4684 / H/L4684<br/>(11 captures ยท 1,179 rx)"]
GW_3578["๐ด Legrand 3578<br/>(Deferred to v2.1+ ยท #879)"]
end
subgraph Subsystems["โ๏ธ Protocol Subsystems & Edge Scenarios"]
SUB_LIGHT["๐ข Lighting & Dimmers (WHO 1)<br/>(5,244 rx ยท 86 captures)"]
SUB_DALI["๐ข DALI DT8 & HSV (WHO 1)<br/>(18 rx ยท 2 captures)"]
SUB_TIMER["๐ข DIN Bus Timers (WHO 1)<br/>(8 rx ยท 5 captures)"]
SUB_GRP["๐ข Lighting Groups (WHO 1)<br/>(27 rx ยท 10 captures)"]
SUB_COV_V["๐ข Covers Timed & Calibrated (WHO 2)<br/>(1,404 rx ยท 55 captures)"]
SUB_COV_H["๐ข Covers Dim 10 / 11 (WHO 2)<br/>(495 rx ยท 25 captures)"]
SUB_COV_255["๐ก Uncalibrated Dim 10=255 (WHO 2)<br/>(Unit tests only)"]
SUB_THERMO_ZONES["๐ข Zone Thermostats & Probes (WHO 4)<br/>(8,665 rx ยท 79 captures)"]
SUB_CU3550["๐ข Central Unit 3550 (WHO 4)<br/>(236 rx ยท 20 captures)"]
SUB_CU4695["๐ด Central Unit 4695 (WHO 4)<br/>(Physical capture needed)"]
SUB_FANCOIL["๐ข Fancoils Dim 11/20 (WHO 4)<br/>(342 rx ยท 25 captures)"]
SUB_ALARM["๐ข Burglar Alarm (WHO 5)<br/>(273 rx ยท 12 captures)"]
SUB_DOOR["๐ข Door Entry (WHO 6/8)<br/>(42 rx ยท 5 captures)"]
SUB_DRY["๐ข AUX & Dry Contacts (WHO 9/25)<br/>(210 rx ยท 15 captures)"]
SUB_CEN["๐ข CEN / CEN+ Triggers (WHO 15/25)<br/>(95 rx ยท 20 captures)"]
SUB_SCENARIOS["๐ข Scenarios (WHO 0/17)<br/>(33 rx ยท 7 captures)"]
SUB_LOCK14["๐ข Actuator Locks (WHO 14)<br/>(24 rx ยท 6 captures)"]
SUB_WHO16["๐ข Audio Matrix (WHO 16)<br/>(431 rx ยท 22 captures)"]
SUB_WHO22["๐ข Sound Diffusion & RDS (WHO 22)<br/>(404 rx ยท 18 captures)"]
SUB_ENERGY["๐ข Energy Metering (WHO 18)<br/>(1,425 rx ยท 27 captures)"]
SUB_DIAG["๐ข Gateway Identity (WHO 13/1013)<br/>(1,204 rx ยท 80 captures)"]
SUB_ROUTER["๐ข F422 Cross-Bus (#4#bus)<br/>(411 rx ยท 14 captures)"]
end
subgraph Engine["๐งช CI Replay & Regression Suite"]
HARNESS["tests/test_trace_replay.py & fixture tests<br/>(Deterministic On-Wire Replay)"]
end
GW_MHS1 --> HARNESS
GW_F454 --> HARNESS
GW_F455 --> HARNESS
GW_F459 --> HARNESS
GW_F461 --> HARNESS
GW_MH202 --> HARNESS
GW_MH201 --> HARNESS
GW_MH200N --> HARNESS
GW_MH200 --> HARNESS
GW_F453 --> HARNESS
GW_H4890 --> HARNESS
GW_H4684 --> HARNESS
SUB_LIGHT --> HARNESS
SUB_DALI --> HARNESS
SUB_TIMER --> HARNESS
SUB_GRP --> HARNESS
SUB_COV_V --> HARNESS
SUB_COV_H --> HARNESS
SUB_THERMO_ZONES --> HARNESS
SUB_CU3550 --> HARNESS
SUB_FANCOIL --> HARNESS
SUB_ALARM --> HARNESS
SUB_DOOR --> HARNESS
SUB_DRY --> HARNESS
SUB_CEN --> HARNESS
SUB_SCENARIOS --> HARNESS
SUB_LOCK14 --> HARNESS
SUB_WHO16 --> HARNESS
SUB_WHO22 --> HARNESS
SUB_ENERGY --> HARNESS
SUB_DIAG --> HARNESS
SUB_ROUTER --> HARNESS
classDef covered fill:#2e7d32,stroke:#1b5e20,color:#ffffff;
classDef partial fill:#f57f17,stroke:#e65100,color:#ffffff;
classDef needed fill:#c62828,stroke:#b71c1c,color:#ffffff;
class GW_MHS1,GW_F454,GW_F455,GW_F459,GW_F461,GW_MH202,GW_MH201,GW_MH200N,GW_MH200,GW_F453,GW_H4890,GW_H4684,SUB_LIGHT,SUB_DALI,SUB_TIMER,SUB_GRP,SUB_COV_V,SUB_COV_H,SUB_THERMO_ZONES,SUB_CU3550,SUB_FANCOIL,SUB_ALARM,SUB_DOOR,SUB_DRY,SUB_CEN,SUB_SCENARIOS,SUB_LOCK14,SUB_WHO16,SUB_WHO22,SUB_ENERGY,SUB_DIAG,SUB_ROUTER covered;
class SUB_COV_255 partial;
class GW_3578,SUB_CU4695 needed;
๐๏ธ Table 1: Gateway Models & Hardware Transports¶
| Gateway Model | Status | Current Evidence / Fixture | Community Trace Needed / Target Scenario |
|---|---|---|---|
| MyHomeServer1 (MHS1) | ๐ข Covered | 47 physical captures (6,879 rx frames; WHO = 1, 2, 4, 7, 8, 9, 13, 14, 15, 18, 22, 25, 1000, 1001, 1013) โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/myhomeserver1_live_2026-10-25/ |
None needed โ cloud/local hybrid gateway plant active in CI. |
| F454 | ๐ข Covered | 23 physical captures (4,447 rx frames; WHO = 0, 1, 2, 4, 5, 9, 13, 14, 18, 25, 1013) โ e.g. tests/fixtures/traces/issue_429/, tests/fixtures/traces/issue_466/ |
None needed โ high-speed multi-session IP webserver active in CI. |
| F455 | ๐ข Covered | 10 physical captures (565 rx frames; WHO = 1, 2, 4, 13, 25, 1001, 1013) โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/central_restore_3100_live_2026-11-12/ |
None needed โ single-bus DIN IP gateway active in CI. |
| F459 | ๐ข Covered | 1 physical capture (898 rx frames; WHO = 1, 2, 4, 13, 1013) โ e.g. tests/fixtures/traces/issue_466/ |
None needed โ WHO 1013 code 65 & WHO 4 capture active in CI. |
| F461 Web Server | ๐ข Covered | 19 physical captures (2,872 rx frames; WHO = 1, 2, 4, 13, 14, 1001, 1013) โ e.g. tests/fixtures/traces/f461_live_2026-10-24/, tests/fixtures/traces/f461_live_2026-10-15/ |
None needed โ DIN Ethernet Web Server (DALI DT8 & fancoils) active in CI. |
| MH202 | ๐ข Covered | 9 physical captures (672 rx frames; WHO = 1, 2, 4, 5, 6, 8, 9, 13, 14, 16, 18, 22, 25, 1013) โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/mh202_sound_intercom_ducking/ |
None needed โ modern scenario programmer plant active in CI. |
| MH201 | ๐ข Covered | 9 physical captures (970 rx frames; WHO = 0, 1, 2, 4, 13, 15, 18, 25) โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/mh201-fresh-discovery-20260930.log |
None needed โ single-worker scenario programmer plant active in CI. |
| MH200N | ๐ข Covered | 16 physical captures (1,664 rx frames; WHO = 0, 1, 2, 4, 5, 9, 13, 15, 16, 17, 18, 22, 25, 1001, 1013, 1022) โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/f500_tuner/ |
None needed โ second-generation scenario programmer active in CI. |
| MH200 (Legacy) | ๐ข Covered | 12 physical captures (1,332 rx frames; WHO = 1, 2, 5, 6, 8, 9, 13, 16, 17, 1001, 1013) โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/mh200_sound_f441m/ |
None needed โ legacy single-session plant & F441M audio active in CI. |
| F452 / F453 / F453AV | ๐ข Covered | Traced F453AV, F453: 10 physical captures (1,065 rx frames; WHO = 1, 2, 4, 5, 13, 25, 1001, 1013) โ e.g. tests/fixtures/traces/issue_619/, tests/fixtures/traces/discussion_770_f453_n4692/ |
Family covered by physical F453AV & F453 captures; optional legacy F452 / F452V captures welcomed. |
| H4890 / AM4890 / 067292 | ๐ข Covered | Traced H4890, 067292: 5 physical captures (983 rx frames; WHO = 1, 2, 4, 5, 9, 13, 16, 18, 22, 25) โ e.g. tests/fixtures/traces/issue_832/, tests/fixtures/traces/issue_466/ |
None needed โ 3.5" touchscreen IP gateways (BTicino & Legrand) active in CI. |
| H4684 / H/L4684 | ๐ข Covered | Traced H/L4684: 11 physical captures (1,179 rx frames; WHO = 1, 2, 3, 4, 5, 6, 9, 13, 16, 22, 1001, 1004) โ e.g. tests/fixtures/traces/issue_466/ |
None needed โ colour touchscreen IP gateway (FW 2.x & 6.x) active in CI. |
| Legrand 3578 USB/Serial | ๐ด Deferred (v2.1+) | Deferred out of v2.0.0 (Discussion #879) |
Hardware tester & raw serial stream: Active tester + raw byte capture (Issue #466) from a physical OpenZigBee installation (WHERE=<id>#9). |
Table 1 is automatically generated and verified from physical bus captures in tests/fixtures/ and supported models in custom_components/myhome/const.py by scripts/sync_documentation.py.
โ๏ธ Table 2: Subsystems, Dimensions & Edge Scenarios¶
| Subsystem & Domain | Status | Current Evidence / Fixture | Community Trace Needed / Target Scenario |
|---|---|---|---|
| Lighting (WHO = 1) โ Relays & Dimmers | ๐ข Covered | 5,244 physical rx frames across 86 captures on 13 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/issue_629/ |
Baseline covered across standard, 4-digit, and F418/F418U2 dimmers. |
| Lighting (WHO = 1) โ DALI Tunable White & HSV Color | ๐ข Covered | 18 physical rx frames across 2 captures on 1 gateway model โ e.g. tests/fixtures/plants/issue_288_f461_dali_dt8/, tests/fixtures/traces/issue_466/ |
Baseline covered (Dimension 12 HSV & Dimension 14 Kelvin/mireds). |
| Lighting (WHO = 1) โ Native DIN Timers | ๐ข Covered | 8 physical rx frames across 5 captures on 3 gateway models โ e.g. tests/fixtures/plants/issue_311_f454/, tests/fixtures/traces/f461_live_2026-10-15/ |
Preset temporization & Dimension 2 replies covered; optional mid-countdown *#1*WHERE*2*H*M*S## (H/M/S > 0) trace welcomed. |
| Lighting (WHO = 1) โ Groups & General Broadcasts (P7) | ๐ข Covered | 27 physical rx frames across 10 captures on 6 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/f461_live_2026-10-15/ |
None needed โ group (#G) and general (WHERE=0) resync engine active in CI. |
| Covers (WHO = 2) โ Travel-Time Positioning & On-Bus Calibration | ๐ข Covered | 1,404 physical rx frames across 55 captures on 13 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/discussion_856/; plus 23 calibrated cover_travel_times profiles in tests/fixtures/traces/discussion_856/, tests/fixtures/traces/mh200_sound_f441m/ |
Baseline covered (stopwatch myhome.calibrate_cover runs, cover_travel_times profiles, and timed slat pulses active in CI). |
Covers (WHO = 2) โ Advanced Position (Dim 10 / 11) |
๐ข Covered | 495 physical rx frames across 25 captures on 6 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/discussion_770_f454_f401/ |
Baseline covered (F401 / LN4661M2 percentage position; the slat angle is not on the bus). |
Covers (WHO = 2) โ Uncalibrated Hardware Sentinel (Dim 10 LEVEL=255) |
๐ก Synthetic | Unit tests for *#2*WHERE*10*BS*255*...## in tests/test_cover.py (0 physical LEVEL=255 rx frames in tests/fixtures/) |
Uncalibrated actuator trace: Bus capture of an uncalibrated F401, LN4672M2, or 067557 reporting *#2*WHERE*10*BS*255*...## prior to Push&Learn end-stop learning. |
| Thermoregulation (WHO = 4) โ Zone Thermostats, Probes & Humidity | ๐ข Covered | 8,665 physical rx frames across 79 captures on 13 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/issue_429/ |
Baseline covered (zone temperature Dim 0, setpoints Dim 12/14, knob offsets Dim 13 & Dim 60 humidity). |
Thermoregulation (WHO = 4) โ 99-Zone Central Unit 3550 (#0) |
๐ข Covered | 236 physical rx frames across 20 captures on 8 gateway models โ e.g. tests/fixtures/traces/central_restore_3100_live_2026-11-12/, tests/fixtures/traces/issue_466/ |
Baseline covered (#0 master modes, *4*3100*#0## auto restore, & zone sync). |
Thermoregulation (WHO = 4) โ 4-Zone Central Unit 4695 (#0#1) |
๐ด Needed | Synthetic unit tests in tests/test_climate.py only (0 inbound #0#1 rx frames in tests/fixtures/) |
4-zone central unit trace: Physical capture from a plant running a 4-zone 4695 / HD4695 (#0#1) central unit. |
Thermoregulation (WHO = 4) โ Fancoils (Dim 11 / 20) |
๐ข Covered | 342 physical rx frames across 25 captures on 4 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/f461_live_2026-10-15/ |
Baseline covered (Dimension 11 fan speeds & Dimension 20 fan-coil states 5โ8). |
| Burglar Alarm (WHO = 5) | ๐ข Covered | 273 physical rx frames across 12 captures on 7 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/plants/issue_311_f454/ |
Baseline covered (physical 3486 / MH202 partition & zone captures active in CI). |
| Door Entry & Intercom Locks (WHO = 6 / 8) | ๐ข Covered | 42 physical rx frames across 5 captures on 4 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/mh202_sound_intercom_ducking/ |
Baseline covered (door lock release & video intercom call events active in CI). |
| AUX & Dry Contacts (WHO = 9 / 25) | ๐ข Covered | 210 physical rx frames across 15 captures on 9 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/mh202_sound_intercom_ducking/ |
Baseline covered (WHO = 9 auxiliary channels & 3477 / F428 contact sensors). |
| CEN / CEN+ Pushbuttons & Rotary Triggers (WHO = 15 / 25) | ๐ข Covered | 95 physical rx frames across 20 captures on 6 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/issue_434/ |
Baseline covered (short, long-press, repeat & release active in CI); a WHO = 25 rotary capture (WHAT = 25..28) is welcome. |
| Scenarios & Schedulers (WHO = 0 / 17) | ๐ข Covered | 33 physical rx frames across 7 captures on 3 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/f500_tuner/ |
Baseline covered (WHO = 0 activation on an F454, WHO = 17 frames on MH200 / MH200N). |
| Actuator Maintenance Locks (WHO = 14) | ๐ข Covered | 24 physical rx frames across 6 captures on 4 gateway models โ e.g. tests/fixtures/plants/issue_247_myhomeserver1/, tests/fixtures/traces/f461_who14_live_2026-10-18/ |
Baseline covered (hardware pushbutton lock/unlock status frames active in CI). |
| Sound System (WHO = 16) โ Matrix & Streaming Proxy | ๐ข Covered | 431 physical rx frames across 22 captures on 5 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/mh200_sound_f441m/ |
Baseline covered (F441 / F441M matrix routing, group takeover & ducking). |
| Sound Diffusion (WHO = 22) โ FM RDS Tuners & Active-Source Sync | ๐ข Covered | 404 physical rx frames across 18 captures on 5 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/f500_tuner/ |
Baseline covered (F500 / F500N FM RDS tuners on WHO = 22-only & dual-stack gateways, 4#<area> active-source tracking, and H4562 WHO = 22 zone captures). |
| Energy Management & Metering (WHO = 18) | ๐ข Covered | 1,425 physical rx frames across 27 captures on 6 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/issue_907/ |
Baseline covered (F520 / F521 / 3522 active power W and total/daily/monthly Wh energy counters). |
| Gateway Clock, Identity & Diagnostics (WHO = 13 / 1001โ1022) | ๐ข Covered | 1,204 physical rx frames across 80 captures on 13 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/traces/mh200_sound_f441m/ |
Baseline covered (WHO = 13 device type/firmware/clock & WHO = 1013 OBJECT_MODEL). |
F422 Cross-Bus Router (#4#<bus>) |
๐ข Covered | 411 physical rx frames across 14 captures on 4 gateway models โ e.g. tests/fixtures/traces/issue_466/, tests/fixtures/plants/issue_288_f461_dali_dt8/ |
None needed โ physical F422 local-bus routing (#4#01, #4#02, ...) active in CI. |
Table 2 is automatically generated and verified from inbound (rx) OpenWebNet frames and calibration bundles in tests/fixtures/ by scripts/sync_documentation.py.
๐ Dual-Track Guide: How Community Testers Can Submit a Trace¶
We offer two simple ways to contribute real-world bus traces, tailored to your technical setup:
๐ท๏ธ Track A: Zero-CLI via Home Assistant UI (Fastest & Easiest)¶
Ideal for standard users running Home Assistant with the MyHOME integration:
- Sweep the Bus: In Home Assistant, go to Developer Tools > Services and call
myhome.sweep_bus(or trigger it from the Lovelace Bus Monitor Card). This actively queries all lighting, cover, HVAC, and gateway diagnostic states in under 3 seconds. - Download Diagnostics: Navigate to Settings > Devices & Services > MyHOME > click the three dots (
โฎ) > Download diagnostics (or click๐พ Export Trace/๐ Copy Traceon the Bus Monitor card). - Submit: Attach the downloaded
.jsonfile to RFC Discussion #248 or open a GitHub Issue. - Privacy Guarantee: Home Assistant and MyHOME automatically redact all passwords, authentication tokens, and private credentials before exporting.
๐ป Track B: Standalone Python Tool (Test Benches & Integrators)¶
Ideal for installers, bench testers, and developers testing isolated gateways without Home Assistant installed:
- Run the Trace Recorder:
- Active Sweep & Listen: The script automatically executes the diagnostic status sweep, listens for ambient button presses or scenario bursts, and scrubs sensitive credentials.
- Drop & Commit: The tool writes a complete ready-to-test fixture folder in
tests/fixtures/plants/<model>_plant/. - Instant CI Verification: Run
pytest tests/test_trace_replay.pyโ our parameterized test runner automatically discovers and tests your plant with zero additional test code required! Submit a Pull Request.
๐ฌ Community Links & Resources¶
Please share your feedback, real-world bus captures, and questions in our community channels:
๐ GitHub Releases & Changelogs โ Release notes and download archives
๐ Join the Community Discussion on RFC #248
๐ Report Issues or Submit Bus Traces