Gateway Timezone Configuration¶
[!NOTE] What the "Unconfigured timezone on MyHOME gateway" repair issue means, why it happens, how to resolve it across different gateway models, and how Home Assistant automatically clears it.
Summary: When an OpenWebNet gateway has never had its timezone explicitly configured (or was reset), it reports a placeholder sentinel value 999 in its WHO=13 time telemetry frames. Home Assistant flags this via a Repair issue (unconfigured_timezone). Once you configure the correct timezone in the gateway's web UI or MyHOME_Suite, the gateway emits a valid offset and Home Assistant automatically dismisses the repair issue.
Why This Issue Is Raised¶
OpenWebNet gateways manage an internal real-time clock (RTC). The Home Assistant MyHOME integration reads or monitors this clock via WHO=13 (Gateway Management):
- Dimension 0: Time and Date (
*#13**0##) - Dimension 22: Time, Date and Timezone (
*#13**22##)
When a gateway's timezone has not been configured, firmware defaults to emitting a sentinel placeholder value 999 in the timezone parameter:
- Dimension 0 frame:
*#13**0*<HH>*<MM>*<SS>*999## - Dimension 22 frame:
*#13**22*<HH>*<MM>*<SS>*999*<DAY>*<MONTH>*<YEAR>##
Why This Matters¶
- Clock & Timestamp Drift: Without a configured timezone, scheduled scenario triggers and time broadcasts on the SCS bus may diverge from your local daylight saving time or Home Assistant's clock.
- Diagnostic Reliability: Underlying protocol parsers expect a standard UTC offset format (such as
+01:00or numeric minute offsets). While the integration handles999gracefully without crashing, leaving it unconfigured prevents proper clock synchronization.
Step-by-Step Resolution by Gateway Model¶
1. F454, F455, and MyHomeServer1 (Web Administration Interface)¶
- Open a web browser and navigate to the IP address of your gateway (e.g.,
http://192.168.1.xxx). - Log in using your installer credentials (default username/password is typically
admin/admin). - Navigate to System Configuration → Date & Time (or Device Settings → Clock).
- Select your geographic region or local timezone (e.g.
Europe/Rome,Europe/Paris,Europe/Amsterdam, or UTC offset). - (Recommended) Enable NTP Synchronization and configure an NTP server (such as
pool.ntp.org). - Click Save / Apply and allow the gateway to restart its network services if prompted.
2. MH200N, MH201, MH202, and F452 (MyHOME_Suite / TiMyHome)¶
- Launch MyHOME_Suite or TiMyHome on your PC.
- Connect to your gateway via Ethernet (IP) or USB.
- Receive or open the gateway's project configuration.
- Navigate to Gateway Settings / General Parameters → Date & Time.
- Set the correct local time zone and check Automatic Daylight Saving Time (DST) if supported.
- Send the configuration to the gateway and perform a reboot.
Automatic Resolution in Home Assistant¶
You do not need to manually dismiss the repair issue in Home Assistant:
- When the gateway completes its reboot or applies the new clock settings, it broadcasts an updated WHO=13 frame carrying a valid timezone offset.
- Home Assistant listens for this telemetry:
- When a valid offset is received (e.g.
+01:00,+02:00), the integration automatically removes theunconfigured_timezoneissue from Settings → System → Repairs.
Related Documentation¶
- Gateway Identification — Model resolution precedence and model mismatch repairs.