Alarm System Configuration (v0.9.x YAML)¶
[!WARNING] Legacy Configuration: This page describes manual YAML configuration in
/config/myhome.yamlused by MyHOME v0.9.x. In MyHOME v2.0+, alarm entities are configured directly via the Home Assistant user interface or discovered automatically.
Burglar Alarm entities are developed for OpenWebNet WHO = 5 (alarm_control_panel).
Supported Hardware¶
- BTicino 3485 / 3486: Central intrusion alarm units
- BTicino HC4600 / L4600: Keypads and transponder readers
- BTicino 3481: Zone expansion interfaces
- Technical Alarms: Gas / water leak sensors transmitting on WHO 5
Configuration Structure¶
In your /config/myhome.yaml:
f454:
mac: '00:03:50:xx:xx:xx'
alarm_control_panel:
central_alarm:
where: '0'
name: Central Alarm
manufacturer: BTicino
model: 3486
zone_1:
where: '1'
name: Ground Floor Alarm
manufacturer: BTicino
model: 3485
Parameters¶
where(mandatory): OpenWebNet address of the partition or central unit:'0': Central unit / global system broadcast'1'through'8': Specific partition or zonename(mandatory): Friendly name for the entity in Home Assistant.manufacturer(optional): Hardware manufacturer (e.g.BTicino).model(optional): Hardware model (e.g.3486,3485).
Supported States and Features¶
- States:
disarmed: System deactivated / maintenancearmed_home: Partial / perimeter armedarmed_away: Total system armedtriggered: Intrusion alarm, technical alarm, or panic event- Commands:
ARM_AWAY(*5*1*<where>##)ARM_HOME(*5*1*<where>##)DISARM(*5*2*<where>##)TRIGGER(*5*17*<where>##panic alarm)