Skip to content

OpenWebNet Protocol Conformance & Capability Matrix

Authoritative Specification & Verification Baseline
Last Updated: November 17, 2026
Corpus Version: 2.0.0 (455 Fixtures, 21 Subsystems, 1,100+ Automated Conformance Assertions)

This document serves as the verifiable truth for OpenWebNet protocol conformance across the Home Assistant (OpenWebNet-HA/MyHOME) and Python protocol driver (OpenWebNet-HA/OWNd) ecosystem.


1. The Verification Authorities

To prevent divergence and eliminate guesswork, every protocol frame and capability is evaluated against four authorities:

Authority Reference Implementation Role & Authority
1. The Judge Legrand OpenWebNet Official Specification Manuals (interrogated via openwebnet-mcp) Legal Grammar: Defines whether a frame syntax, dimension boundary, or parameter structure is strictly valid per Legrand standards.
2. The Reference Oracle openwebnet4j & openHAB OpenWebNet Binding (by Massimo Valla) Wire Baseline: Provides empirical on-wire factory strings, real-world edge cases, and 10+ years of mature production testing.
3. The Firmware Oracle own-firmware-oracle (tests/golden/firmware_oracle.json, 520 inputs across 12 emulated gateways) Hardware Truth: Provides hash-pinned gateway replies, SCS bus forwarding verdicts, and crash boundaries from real gateway binaries.
4. The SUT OWNd protocol engine & custom_components/myhome runtime System Under Test: Must parse, validate, roundtrip serialize, and build frames with 100% fidelity.

2. Subsystem Conformance & Capability Matrix

WHO Subsystem Verified Operations Canonical Frame Examples Judge (Legrand PDF) Oracles & Captures Runtime Status
- Signaling Gateway ACK / NACK *#*1##, *#*0## Valid Matched VERIFIED (100%)
0 Scenarios Activate, Stop, Execute, Programmer Lock/Unlock *0*1*1##, *0*0*5##, *0*2*05##, *0*41*01## Valid Matched + Live Captures VERIFIED (100%)
1 Lighting ON/OFF, Status, Speed Dimming, Private Bus (#4#01), DALI DT8 Tunable White, RGB/HSV *1*1*0311#4#01##, *1*1#5*12##, *#1*99*#1*150*0## Valid Matched + Live Captures VERIFIED (100%)
2 Automation Shutter UP/DOWN/STOP, Bus Routing (#4#01), Go-to-level Position % (#11#PRIORITY) *2*1*21#4#01##, *#2*93*#11#001*75##, *2*2*93## Valid Matched + Live Captures VERIFIED (100%)
3 Load Control Enabled priority states (#1..#8), Force priority (*3*2*#1##), priority status and CU measurement requests (Dims 0..4, probe-only) *3*1*#8##, *3*1*#1##, *3*2*#1##, *#3*10*0## Valid Firmware Oracle + Capture VERIFIED (100%)
4 Thermoregulation Probe queries (21.5°C), Setpoints, Knob offset (Dim 13), 0–10 V & Fan-coil (Dim 19/20), CU #0 *#4*1*0*0215##, *#4*88*13*13##, *#4*1#3*20*100##, *4*3100*#0## Valid Matched + Live Captures VERIFIED (100%)
5 Burglar Alarm Zone/CU status, Intrusion & battery events, Empty/star-WHERE alarm status frames *5*1*0##, *#5*2##, *5*11*#2##, *5*1*## Valid Matched + Live Captures VERIFIED (100%)
6 Door Entry Door lock release, Staircase light, Camera ON (probe-only), Free-channel short frames, Open lock in conversation *6*10*4000##, *6*10*4003##, *6*9##, *6*22*1## Valid Live Captures VERIFIED (100%)
7 Multimedia External camera video stream open and close (OWNAVCommand) *7*0*4000##, *7*9**## Valid Legrand PDF only (no capture) VERIFIED (100%)
8 Video Intercom Internal/External audio-video calls, Pager broadcast and Status reads (probe-only), Entrance-panel calls, Caller-address report *8*1#1#4#20*11##, *8*1#1#4*74##, *8*9#1#4*20##, *8*1#14#2#11*4## Valid Firmware Oracle + Capture VERIFIED (100%)
9 Auxiliary Relay ON/OFF indications and generic status queries across auxiliary channels *9*1*4##, *9*0*4##, *#9*1## Valid Matched + Live Captures VERIFIED (100%)
13 / 1013 Gateway Mgmt Time/Date/Timezone (999 & empty TZ), Firmware/Kernel/Distro, WHO 1013 object model *#13**0##, *#13**15##, *#13**#0*14*59*05*##, *#1013**1*67*15*5*0## Valid Firmware Oracle + Capture VERIFIED (100%)
14 Actuator Lock Point-to-point & #4#01 routed actuator lock (0) / unlock (1), General unlock event *14*0*11##, *14*0*07#4#01##, *14*1*0## Valid Firmware Oracle + Capture VERIFIED (100%)
15 CEN Scenarios Press, short release, long release, extended hold (#1/#2/#3), 4-digit source addresses *15*02*11##, *15*02#1*11##, *15*02#2*11##, *15*03#3*0512## Valid Firmware Oracle + Capture VERIFIED (100%)
16 Sound System Source ON/OFF, F441M matrix routing, Amplifier volume (Dim 1), RDS (Dim 8) *16*3*101##, *16*3*111##, *#16*23*1*15##, *#16*23*#1*15## Valid Firmware Oracle + Capture VERIFIED (100%)
17 Scene Programmer MH200N / MH202 scene start, stop, enable, disable & status requests *17*1*30##, *17*2*30##, *17*3*30##, *#17*0## Valid Firmware Oracle + Capture VERIFIED (100%)
18 Energy Mgmt Active power (113 W), Cumulative/Monthly/Daily Energy (Wh) (51..54), Stream 1200, Stop & Go *#18*51*113##, *#18*51*51*8151646##, *#18*56*#1200#1*2##, *18*21*11## Valid Firmware Oracle + Capture VERIFIED (100%)
22 Sound Diffusion Multi-parameter speaker/source control, MH200N dual-frame mirror events, Volume/Preset/State *22*1#4#1*3#1#1##, *22*2#4#1*5#2#2##, *#22*3#1#1*#1*17## Valid Firmware Oracle + Capture VERIFIED (100%)
25 CEN+ / Dry Contacts Short press; start, hold and release of an extended press (2OBJECT); ScenarioPlus; dry contacts *25*21#1*21##, *25*22#1*21##, *25*12*131##, *25*31#1*339## Valid Matched + Live Captures VERIFIED (100%)
1001 Lighting Diag Actuator autodiagnostic 24-bit (Dim 7 / Dim 11) bitmasks, Object model/FW/ID, Status request (probe-only) *#1001*0*7*111111111111111101101111##, *#1001*74*11*111110111111111111110111##, *#1001*0*2*1*3*8## Valid Live Captures VERIFIED (100%)
1004 Thermo Diag Central/Probe/Zone 24-bit (Dim 7/11) & 16-bit (Dim 20/21/22) masks, Fault counters (23) *#1004*#0*7##, *#1004*66*11*111111111111111111111111##, *#1004*#66*22*1111111111111111##, *#1004*#0*23## Valid Live Captures VERIFIED (100%)

A probe-only operation is a command or request that a contributor sent to an F461 (firmware 2.0.11) and that the gateway answered with NACK; no stored trace receives it. The matrix counts it as parsed and round-tripped by OWNd, not as a function confirmed on hardware. The fixture notes in tests/golden/frames/ name the trace behind each capture.

Sources for the examples changed in OWNd#77. The MyHomeServer1 firmware, run on an emulated bus, produces a bus frame for each of them and refuses the examples they replace. The WHO 15 press and short release (*15*01*73##, *15*01#1*73##) were captured on an MH200N + MyHomeServer1 bus in MyHOME#541. Long release and extended hold (#2, #3) are verified in both firmware and the four-digit 0512 capture in MyHOME#624. The WHO 25 examples are MH201 and H4890 captures from MyHOME#418 and MyHOME#466. The WHO 13 reads use the published empty-WHERE form *#13**DIMENSION## (Encyclopedia who-13-integration-gateway/dimensions.md "Read form"): in own-firmware-oracle (ownd-audit-frames and who13-clock) all emulated gateways answer *#13**0## and *#13**22## with ACK and the current time, while the WHERE 0 spelling *#13*0*0## is nack, silent; OWNGatewayCommand.request_time() and the event keepalive emit *#13**0##.


3. Key Architectural Truths & Design Decisions

3.1 String Preservation for Hardware Addresses

  • Observation: Addresses such as 0311 (Lighting PTP) and 0110 (CEN) begin with leading zeros.
  • Verifiable Truth: Addresses must never be converted to integers (311 or 110). In OpenWebNet, leading zeros denote specific address spaces and module wiring. OWNd strictly enforces string types for where across all subsystems.

3.2 Private Bus Routing (#4#bus)

  • Observation: Installations with multiple physical SCS buses behind an F454 or 3486 gateway use interface routing (e.g. *1*1*0311#4#01##).
  • Verifiable Truth: The interface routing suffix #4#<interface> is an addressing qualifier, not a dimension parameter. OWNd extracts this cleanly into parsed.interface = '01' and parsed.where = '0311', preserving 100% roundtrip wire string equality.

3.3 Strict Standards vs. Tolerant Synthesis (The Alarm WHERE Omission)

  • Observation: In openwebnet4j, frame *5*7*## (Alarm) synthesizes WHERE = '0' when the address is omitted, while gateways without a panel answer *#5*0## with *5*9*##.
  • Verifiable Truth: OWNd parses empty-WHERE alarm status frames (*5*9*##) with where == "" so consumers never synthesize a phantom zone 0 device, while outbound command builders require an explicit address.

3.4 Extended Thermoregulation (Dimension 12 Setpoint After Local Offset)

  • Observation: Dimension 12 is the complete probe status: its value is the zone's setpoint after the local offset, not a measured temperature (Encyclopedia who-4-temperature-control/dimensions.md, "DIMENSION 12 - complete probe status": *#4*WHERE*12*T*3##, T in 0020..0430; measured temperatures are Dimension 0). The openwebnet4j fixture *#4*6*12*1048*3## carries a signed value the published range does not include.
  • Verifiable Truth: The value parameter 1048 decodes as -4.8°C with the SXXX sign rule (the initial 1 indicates negative sign; 048 is tenths of a degree). OWNd stores it in local_set_temperature (message_type local_target_temperature); main_temperature stays None.

4. Independent Local Verification

Any contributor or user can independently verify the conformance suite:

# Run automated assertions against the 455-fixture golden corpus
python -m pytest tests/test_golden_conformance.py tests/test_golden_privacy.py

# Run non-mutating schema, privacy & corpus.json sync validation
python tools/golden/validate_corpus.py --check