Skip to content

Integration Services Reference

This document provides a comprehensive reference for all custom services registered by the MyHOME integration in Home Assistant.


📋 Services Summary

Service Target Description
myhome.send_message Gateway Send an arbitrary (but valid) OpenWebNet message to the gateway.
myhome.turn_on_timed light, switch Turn on a light or switch with a hardware-offloaded SCS bus timer that turns off automatically even if Home Assistant restarts.
myhome.sync_time Gateway Synchronize gateway's time to HA local time.
myhome.start_sending_instant_power sensor Get automatic instant power draw updates for a sensor.
myhome.stop_sending_instant_power sensor Stop automatic instant power draw updates for a sensor.
myhome.sweep_bus Gateway Triggers an active read-only status query across all bus subsystems (lighting, covers, thermoregulation, clock, and gateway diagnostics) to populate the diagnostic bus monitor ring buffer.
myhome.calibrate_cover cover Measures a timed cover's up and down travel times on the SCS bus and stores them. The cover is driven fully up, then fully down (timed), then fully up again (timed). Covers are calibrated one at a time per gateway. Do not run while the shutter must stay put.
myhome.stop_cover_calibration Gateway Stops the running travel-time calibration and cancels the queued ones. The moving cover is stopped; nothing is stored. Without a gateway every gateway is stopped.
myhome.set_cover_travel_time cover Stores the physical travel times of a timed cover by hand (measured with a stopwatch) instead of calibrating on the bus. Values are kept in the config entry, survive restarts and apply to discovered covers without YAML.
myhome.reset_cover_travel_time cover Forgets the measured or manually set travel times of a timed cover and returns to the myhome.yaml travel_time or the 25 s default.
myhome.tuner_seek_up media_player Seek forward to the next receivable FM radio frequency on an F500 tuner source.
myhome.tuner_seek_down media_player Seek backward to the previous receivable FM radio frequency on an F500 tuner source.
myhome.send_scenario_plus_command Gateway Send a WHO 25 scenario plus command (on, off, increase, decrease, stop) to an addressed scenario plus object.
myhome.cancel_cover_request cover Cancels a pending approval request or a running pre-warning of an impulse gate or garage door. Cancelling is always safe; nothing moves.
myhome.acknowledge_cover_fault cover Clears the fault latched when a gate or garage door did not reach the expected state after a pulse (possible obstacle or reversal). Only an allowed user who is at home may acknowledge it; until then closing from Home Assistant stays blocked.
myhome.tuner_set_frequency media_player Tune directly to a manual FM radio frequency (87.50–108.00 MHz) on an F500 / F500N tuner source.
myhome.tuner_store_station media_player Memorise the currently tuned FM radio frequency into a preset station slot (1–15) on an F500 / F500N tuner source.

1. myhome.send_message

Sends an arbitrary, valid OpenWebNet message through the gateway command session. The integration validates syntax, dispatches the frame, and logs the transaction to the Bus Monitor.

Warning

WHO = 4 Dimension 22 Firmware Crash Guard (is_refused_dimension_22): Non-split WHO = 4 Dimension 22 frames whose WHERE carries no actuator token (such as a zone *#4*1*22##, the general address *#4*0*22##, or the central unit *#4*#0*22##) kill the thermostat daemon on Linux IP gateways (F461, F454, MH200N, etc.) and are strictly refused before reaching the socket. Published split-unit forms (*#4*3#Z#N*22## and *#4*3#Z#N*#22*MOD*SP*VEL*SWING##) are safe across all twelve emulated gateway firmwares and are permitted.

Fields

Parameter Type Required Description Example
gateway string No The MAC address of the target gateway (defaults to the is_primary gateway, or the first loaded gateway if none is primary). Unknown keys such as gw_mac are rejected. "00:03:50:20:00:01"
message string Yes Valid OpenWebNet frame ending with ##. "*1*0*0##"

Example YAML Call

action: myhome.send_message
data:
  gateway: "00:03:50:20:00:01"
  message: "*1*0*0##" # General turn off all lights

2. myhome.turn_on_timed

Turns on an individual WHO = 1 light or switch actuator with a hardware-offloaded SCS timer.

Tip

Why use this service? Standard Home Assistant timers (e.g. delay: 00:02:00 followed by light.turn_off) will fail if Home Assistant restarts or crashes during the delay. myhome.turn_on_timed programs the hardware actuator itself to count down and power off autonomously on the physical bus.

Note

Supported Entities: myhome.turn_on_timed applies only to individual point-to-point WHO = 1 light and switch actuators (0.5–918,000 seconds via preset WHAT codes or Dimension 2 *#1*WHERE*#2*H*M*S##). Calling it on an SCS group light (#G, group_no_timer), a WHO = 4 probe-less thermo switch (thermo_switch_no_timer), or a WHO = 9/25 Invert state configuration switch (invert_switch_no_timer) raises a ServiceValidationError.

Fields

Parameter Type Required Description Example
duration float No Total duration in seconds (0.5 to 918,000 s — 0.5 s impulse preset up to 255 hours via Dimension 2). 120
hours integer No Hours component (0–255). 0
minutes integer No Minutes component (0–59). 5
seconds float No Seconds component (0–59). 30
brightness integer No Brightness level (1–255) for dimmable lights. 200
brightness_pct integer No Brightness percentage (1–100%) for dimmable lights. 80

(Note: Specify duration directly, or specify custom hours/minutes/seconds.)

Example YAML Call

action: myhome.turn_on_timed
target:
  entity_id: light.hallway_staircase
data:
  minutes: 3
  seconds: 30
  brightness_pct: 70

3. myhome.sync_time

Synchronizes the gateway's real-time clock (RTC) with Home Assistant's local time using WHO = 13 dimension frames. This ensures scheduled events programmed directly inside physical gateways (e.g. MH200N/MH202 schedules) run in lockstep with real time.

Note

  • Shared-Bus Topology: When gateway is omitted, follower (secondary / standby) gateways on a shared SCS bus are automatically skipped so only primary gateways broadcast clock updates.
  • Whole-Hour UTC Offset Requirement: Because the OpenWebNet WHO = 13 timezone offset field (0HH / 1HH) only encodes whole hours, calling myhome.sync_time when Home Assistant is configured in a fractional-hour timezone (such as Asia/Kolkata +05:30) raises ServiceValidationError (sync_time_unsupported_offset) rather than transmitting a truncated offset.

Fields

Parameter Type Required Description Example
gateway string No Target gateway MAC address (defaults to all primary gateways). "00:03:50:20:00:01"

Example YAML Call

action: myhome.sync_time
data:
  gateway: "00:03:50:20:00:01"

4. myhome.start_sending_instant_power

By default, MyHOME energy meters (F520, F521, F522, F523, 3522) transmit energy readings periodically to conserve bus bandwidth. Calling this entity service instructs the targeted power sensor's meter to stream high-frequency instant power updates (Dimension 113) for a bounded window (1–255 minutes, default 65). To stop streaming early, call myhome.stop_sending_instant_power (duration: 0 is rejected by schema validation).

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME sensor entity (device_class: power). sensor.general_power
duration integer No Duration in minutes (1–255, default 65) to keep streaming instant power; call myhome.stop_sending_instant_power to stop early. 65

Example YAML Call

action: myhome.start_sending_instant_power
target:
  entity_id: sensor.heat_pump_power
data:
  duration: 65

5. myhome.stop_sending_instant_power

Stops active high-frequency instant power streaming from an energy meter, returning the meter to its default periodic transmission mode.

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME sensor entity (device_class: power). sensor.general_power

Example YAML Call

action: myhome.stop_sending_instant_power
target:
  entity_id: sensor.heat_pump_power

6. myhome.sweep_bus

Actively queries status across all configured subsystems (lighting, automation, thermoregulation, and gateway diagnostics). It is used to refresh entity states and populate the in-band Bus Monitor with fresh data for troubleshooting.

Note

With the default force: false the service sends the same general requests as the startup sweep, so on the gateways whose firmware drops *#4*0## before the bus (F450, F454, F459, F460, F461, H4684, MH200, MH201, MH202 and MyHomeServer1) it sends no WHO 4 frame at all: the general request is left out and the service triggers no per-zone *#4*<WHERE>## or *#4*<WHERE>*0## poll (those belong to the climate entities' own polling, see climate). *#16*0*5## is left out the same way on F450, F459, F460, F461, MH202 and MyHomeServer1. With force: true the requests are sent, and the firmware still drops them before they reach the bus (a NACK on the command session, nothing on the event session).

Fields

Parameter Type Required Description Example
gateway string No Target gateway MAC address (defaults to all gateways). "00:03:50:20:00:01"
force boolean No Force probe across all subsystems regardless of gateway profile restrictions, including the general requests the gateway firmware drops (*#4*0##, *#16*0*5## on most models; see runtime behaviour). Defaults to false, which sends the same general requests as the startup sweep. true

Example YAML Call

action: myhome.sweep_bus

7. myhome.calibrate_cover

Measures a timed cover's travel times on the bus and stores them, replacing the guessed travel_time. The cover is driven fully up (so its position is known), then fully down (timed), then fully up again (timed). Covers of one gateway are calibrated one at a time — a single-session gateway cannot drive two motors reliably and overlapping runs would confuse the timing. The shutter moves for about three full travels; do not run it while the shutter must stay put.

The measured values are the actuator's run times (motor start → actuator stop status). They equal the physical travel when the installer calibrated the actuator's run-time parameter to closely match the real travel (e.g. by setting the M configurator or virtual configuration in MyHOME_Suite). An actuator left at its factory default 60 s run-time limit (reported with M=0, last_run_seconds ~60–61 s) stops itself, not at the end stop: such a run ends at about 60–61 s and is refused (failed, nothing stored) as soon as it ends, whoever called the service. For that shutter, you can either adjust the actuator's timed stop setting in MyHOME_Suite (to a couple of seconds above the real travel when the shutter takes under ~58 s; above 60 s only whole-minute steps exist), or without touching the actuator, stop a run by hand (wall switch or the cover's Stop) once it reaches the end stop, read last_run_seconds from the cover's attributes and store it with myhome.set_cover_travel_time.

The guard catches only the configurator's whole-minute limits: a run ending from 1 s before a limit to 5 s per minute after it — 59–65 s at 60 s, 119–130 s at 120 s (the M=1 setting a 60–86 s shutter needs on an F411/2 or F411/4, and ~125.5–127.1 s observed on 4672 actuators in #433), 179–195 s at 180 s, and so on up to 10 min. The failed event then carries actuator_limit (the limit in seconds). Limits above 3 min (and a 3 min stop arriving after the 180 s wait) fail first on the 180 s wait for the stop status. An actuator whose run-time parameter the installer set significantly longer than the physical travel stops itself when its timer expires, and that duration is stored as the travel time: nothing on the bus tells it apart from a real end stop, only a stopwatch can. If the stored time is longer than the shutter visibly takes to move, time a run stopped by hand (last_run_seconds) or set travel_time manually with myhome.set_cover_travel_time.

Results are stored in the config entry options (cover_travel_times), survive restarts and reinstalls, apply to discovered covers without any YAML, and show up as entity attributes: travel_time_down, travel_time_up, calibration_source (measured / manual / copied / yaml / default), calibrated_at (and copied_from when copied). Every run of a timed cover is measured the same way, calibration or not: motion_started_at is the motor-start anchor of the current run and last_run_seconds / last_run_direction / last_run_ended_at describe the last completed run (motor start → stop frame written, re-anchored to the stop status when relayed, or actuator stop status), so a run stopped by hand at the end stop gives the physical travel without the calibration service. Advanced covers (which report their position) are refused. Progress is published on the event bus as myhome_cover_calibration (phase: queued, start, run, done, failed).

The same action sits behind the Calibrate travel time button on every timed cover's device page (button.<cover name>_calibrate_travel_time), and the Calibrate all covers button on the gateway device (button.<gateway name>_calibrate_all_covers), which targets every enabled cover of that gateway at once and lets the lock serialise them.

Fields

Parameter Type Required Description Example
entity_id target Yes One or more MyHOME cover entities (all for every cover). cover.bedroom_shutter

Example YAML Call

action: myhome.calibrate_cover
target:
  entity_id:
    - cover.bedroom_shutter
    - cover.kitchen_shutter

8. myhome.stop_cover_calibration

Stops the calibration that is running and cancels every cover still queued behind it. The moving cover receives a stop command, its calibration event reports phase: failed with Calibration stopped by user, and nothing is stored. Without a gateway every gateway's queue is cleared. Also available as an entity service on any cover (targets that cover's gateway).

Fields

Parameter Type Required Description Example
gateway string No Gateway MAC address; all gateways when omitted. 00:03:50:20:00:01

Example YAML Call

action: myhome.stop_cover_calibration

9. myhome.set_cover_travel_time

Stores the physical travel times of a timed cover by hand — the manual alternative to calibrate_cover for gateways that cannot calibrate reliably (MH200 / MH200N single-session pacing, or actuators at a configurator run-time limit such as 60 s or 120 s). Measure the closing and opening runs with a stopwatch and pass them here. travel_time fills whichever direction has no explicit value; note that travel_time_down on its own also sets the up time (the two are assumed equal unless travel_time_up is given), whereas travel_time_up on its own leaves the stored down time untouched — pass both when you only want to change one. Travel times must lie between 1 s and 300 s. The motor start-up floor (min_motor_pulse) can also be configured here (0.0 to 5.0 s, 0.0 disables). When setting travel times, the result is stored like a measured calibration (calibration_source: manual); when only min_motor_pulse is specified, existing travel times, source, and calibration timestamps remain untouched.

Fields

Parameter Type Required Description Example
entity_id target Yes One or more MyHOME timed cover entities. cover.bedroom_shutter
travel_time float No* Seconds for a full travel, both directions. 24.5
travel_time_down float No* Seconds for a full closing run. 24.5
travel_time_up float No* Seconds for a full opening run. 26.0
slat_time float No* Seconds a Venetian blind (slat_tilt: true) needs for a full slat rotation, 0.5-10 s. Stored on its own it does not touch the stored travel times, and it also works on covers that report their position. It survives restarts, also for covers declared in myhome.yaml (where it wins over the yaml slat_time); reset_cover_travel_time returns it to the yaml value or the 2 s default. 2.0
copied_from entity id No The cover the times were taken from; calibration_source becomes copied and copied_from is exposed as an attribute. cover.living_room_west
min_motor_pulse float No Minimum duration in seconds (0.0–5.0) of a motor pulse to overcome mechanical deadband and brake inertia. Defaults to 0.4 s (0.0 disables). 0.4

* at least one of the time fields or min_motor_pulse is required.

Example YAML Call

action: myhome.set_cover_travel_time
target:
  entity_id: cover.bedroom_shutter
data:
  travel_time_down: 24.5
  travel_time_up: 26.0
  min_motor_pulse: 0.3

10. myhome.reset_cover_travel_time

Forgets the measured or manually set travel times of a timed cover. The cover returns to the travel_time from myhome.yaml when one is configured, otherwise to the 25 s default, and calibration_source reports yaml / default again. A stored slat_time returns to the yaml value or the 2 s default as well. On a position-reporting Venetian blind (advanced_shutter and slat_tilt) the service only resets the slat_time; other position-reporting covers refuse it.

Fields

Parameter Type Required Description Example
entity_id target Yes One or more MyHOME timed cover entities. cover.bedroom_shutter

Example YAML Call

action: myhome.reset_cover_travel_time
target:
  entity_id: cover.bedroom_shutter

11. myhome.tuner_seek_up

Commands an F500 / F500N sound source tuner entity (WHERE 101–109) to seek forward (*16*5000*10S##) to the next receivable FM radio frequency on the SCS bus.

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME tuner source media_player entity. media_player.audio_source_1

Example YAML Call

action: myhome.tuner_seek_up
target:
  entity_id: media_player.audio_source_1

12. myhome.tuner_seek_down

Commands an F500 / F500N sound source tuner entity (WHERE 101–109) to seek backward (*16*5100*10S##) to the previous receivable FM radio frequency on the SCS bus.

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME tuner source media_player entity. media_player.audio_source_1

Example YAML Call

action: myhome.tuner_seek_down
target:
  entity_id: media_player.audio_source_1

13. myhome.send_scenario_plus_command

Sends a WHO 25 scenario plus command (on, off, increase, decrease, or stop) to an addressed scenario plus object on the SCS bus.

Note

For increase and decrease actions, step and speed parameters are fixed to standard Legrand protocol defaults (#0#5, as confirmed by physical gateway traces); they are not user-configurable in this service.

Fields

Parameter Type Required Description Example
gateway string No The MAC address of the target gateway (defaults to primary). "00:03:50:20:00:01"
where string Yes The scenario plus object address on the bus. "11"
action string Yes The scenario plus action (on, off, increase, decrease, stop). Step and speed for increase/decrease are fixed to standard defaults (#0#5). "on"

Example YAML Call

action: myhome.send_scenario_plus_command
data:
  where: "11"
  action: "on"

14. myhome.cancel_cover_request

Cancels an active or pending approval request or a running 5-second pre-warning countdown of an impulse gate or garage door (type: impulse_relay). Cancelling is always safe: no bus impulse is sent, no relay energizes, and nothing moves. Only meaningful for a cover with an access: block; on a cover without one the service raises an error.

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME impulse cover entity. cover.garage_door_1

Example YAML Call

action: myhome.cancel_cover_request
target:
  entity_id: cover.garage_door_1

15. myhome.acknowledge_cover_fault

Clears the safety fault latched when a gate or garage door did not reach its expected state after a pulse (indicating a physical obstacle, safety trip, or reversal). Only an allowed user who is physically at home may clear the fault. Until acknowledged, all remote and automated closing commands from Home Assistant remain strictly blocked. The fault survives a restart or reload of Home Assistant. Only meaningful for a cover with an access: block.

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME impulse cover entity currently in fault. cover.garage_door_1

Example YAML Call

action: myhome.acknowledge_cover_fault
target:
  entity_id: cover.garage_door_1

16. myhome.tuner_set_frequency

Tunes an F500 / F500N sound source tuner entity (WHERE 101–109 / WHO 22 2#S) directly to an explicit FM radio frequency (87.50–108.00 MHz, 0.05 MHz step), dispatching *#16*10S*#6*0*<kHz>## on WHO 16 gateways or *#22*2#S*#5*1*<10kHz>## on WHO 22-only gateways (MyHomeServer1, F461). You can also adjust this directly in the UI via the companion number.<source>_frequency entity.

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME tuner source media_player entity. media_player.audio_source_1
frequency float Yes Target FM radio frequency in MHz (87.5–108.0, 0.05 MHz step). 105.3

Example YAML Call

action: myhome.tuner_set_frequency
target:
  entity_id: media_player.audio_source_1
data:
  frequency: 105.3

17. myhome.tuner_store_station

Memorises the currently tuned FM radio frequency into a hardware preset slot (1–5 on F500, up to 1–15 on F500N), dispatching *#16*10S*#10*<station>## for slots 1–5 on WHO 16 gateways (bt_difson ceiling) and *22*33#<station>*2#S## for extended slots 6–15 on dual-stack gateways or all slots 1–15 on WHO 22-only gateways (WHO 16-only gateways such as MH200 reject slots 6–15).

Fields

Parameter Type Required Description Example
entity_id target Yes Target MyHOME tuner source media_player entity. media_player.audio_source_1
station integer Yes Preset memory slot number (1–5 on WHO 16-only gateways, 1–15 when WHO 22 is available). 5

Example YAML Call

action: myhome.tuner_store_station
target:
  entity_id: media_player.audio_source_1
data:
  station: 5