Climate & Heating (WHO = 4)

The MyHOME integration provides full control for heating, cooling, central thermoregulation units, and zone thermostats operating on OpenWebNet WHO = 4.

In v2, setup and management are 100% UI-first: climate zones and central units are automatically discovered over the SCS bus without manual YAML configuration files.


🚀 Auto-Discovery

When your gateway connects to Home Assistant:

  1. Dynamic Bus Discovery: The integration listens to OpenWebNet WHO = 4 temperature and setpoint messages broadcast on the SCS bus.
  2. Entity Creation: Each active thermoregulation zone (WHERE = 1..99 or central unit #0) is registered as a Home Assistant climate entity linked to your gateway.
  3. UI Customization: You can rename the zone, assign it to an Area (e.g. Master Bedroom, Living Room), and adjust temperature step increments directly in the Home Assistant UI.

🏛️ Supported Plant Architectures

MyHOME installations typically deploy one of three climate topologies, all natively supported by the v2 discovery engine:

1. 99-Zone Central Unit Architecture (BTicino 3550 / #0)

  • Hardware: Central thermoregulation unit (BTicino 3550, MyHOME_Screen 10, or MyHOME_Screen 3.5) operating at master address WHERE = #0.
  • Subordinate Zones: Individual room zones (WHERE = 1..99) with local probes (L4693, H4693, LN4693, etc.) and F430/2 or F430/4 flush/DIN actuators.
  • Operation: The integration discovers the central unit (#0) as the master climate entity and each individual zone (1..99) as a controllable climate device. Subordinate zone setpoint and mode commands use the central-unit-routed #Z address format (*#4*#Z*#14*TTTT*M##, *4*311*#Z##, *4*303*#Z##).
  • Startup & Reconnect Status Burst (*#4*#0##): On startup (including on SCS-only gateways such as MH200N and F454), the central unit entity queries *#4*#0##. The 3550 responds with its operating mode frame (e.g. *4*1101*#0## for Heating Weekly Program 1, *4*110#0200*#0## for Manual 20.0 °C, or *4*102*#0## for Antifreeze/Protection) followed by diagnostic status frames (WHAT 20..24, 30, 31), exposed on the #0 entity as state attributes:
  • remote_control: "enabled" (*4*21*#0##) or "disabled" (*4*20*#0##, raises the self-clearing central_remote_control_disabled repair issue).
  • at_least_one_probe_off: true when *4*22*#0## is reported in the current burst.
  • at_least_one_probe_antifreeze: true when *4*23*#0## is reported in the current burst.
  • at_least_one_probe_manual: true when *4*24*#0## is reported in the current burst.
  • failure_detected: true when *4*30*#0## (Failure discovered in a zone) is reported in the current burst.
  • battery_fault: true when *4*31*#0## (Central unit battery KO) is reported in the current burst (raises the self-clearing central_battery_fault repair issue).
  • Remote Control (Telegestione) Requirement: On a physical BTicino 3550, Remote Control (Telegestione) must be set to Enabled (Abilitata) in the 3550 menu (*4*21*#0##) for the central unit to accept remote commands over the bus. When *4*20*#0## is active, the gateway still replies *#*1## (ACK), but the 3550 ignores remote mode and setpoint writes.
  • Subordinate Zone Control Patterns (Auto vs Manual):
Control Pattern Central Unit (#0) Mode Subordinate Zone (1..99) Mode How Setpoint & Schedule Changes Work
1. 3550 as Schedule Master + HA Temporary Overrides auto (Weekly Program 1..3 or Scenario 1..16) auto (*4*111*#Z## / *4*211*#Z##) Calling climate.set_temperature on a zone writes *#4*#Z*#14*TTTT*3##, placing that zone into manual setpoint override (*4*110*#Z##, hvac_mode: heat/cool, #0 reports at_least_one_probe_manual: true). Setting the zone's hvac_mode back to auto sends *4*311*#Z## and returns the zone to the 3550's active weekly schedule.
2. Home Assistant as Full Schedule Master heat, cool, or auto heat / cool (Manual setpoint per room) Each zone is driven directly by Home Assistant automations or the HA Schedule integration calling climate.set_temperature (*#4*#Z*#14*TTTT*3##) or climate.set_hvac_mode (heat, cool, off) on each room entity independently.

2. 4-Zone Central Unit Architecture

  • Hardware: BTicino HC4695, L4695, or LN4695 4-zone master display panel.
  • Operation: The master panel acts as Zone 1 (or its assigned zone number) while coordinating up to three subordinate zones.

3. Standalone Probes (No Central Unit)

  • Hardware: Autonomous room thermostats (BTicino H4691, LN4691, L4692) acting as independent temperature controllers without a master central display.
  • Operation: Each thermostat is exposed directly as an independent climate entity with full target setpoint and mode control.

🌡️ Push-Driven Secondary Probes (WHERE ≥ 100)

In plants with secondary temperature sensors (e.g. BTicino 3455 radio probes connected via L4577 radio interfaces), sensor addresses have 3 digits (e.g. WHERE = 105 corresponds to the first secondary probe of Zone 5).

  • Push-Driven Telemetry: These battery-powered or radio sensors broadcast their temperature updates periodically on the SCS bus and actively reject direct poll requests.
  • v2 Quiet Listening: The v2 climate engine recognizes secondary probe addresses, operates in receive-only mode, and suppresses redundant polling to prevent gateway NACKs.

🎛️ Supported Features & HVAC Modes

MyHOME climate entities support standard Home Assistant climate controls:

  • HVAC Modes:
  • heat: System active in heating mode.
  • cool: System active in cooling / air-conditioning mode.
  • auto: Following scheduled setpoint or central program.
  • off: System frost-protection or thermal shutdown.
  • Target Temperature: Adjustable setpoint slider in 0.5 °C increments. The slider shows the setpoint the thermostat regulates to (dimension 12, knob offset included) whenever the zone has reported it; the commanded setpoint (dimension 14) is only shown until then. On an F461 the two can differ (21.0 commanded, 23.5 in force on a live capture), and the attribute local_target_temperature carries the same value. When the zone leaves off, the value reported while it was off is taken as the protection setpoint (#383), so the commanded setpoint is shown until the zone reports dimension 12 again; after a set_temperature call the next report, dimension 12 or 14, is shown. The value restored after a restart of Home Assistant already carries the saved local_offset, so the first dimension 13 report does not add it again.
  • Current Temperature: Real-time ambient reading reported by the probe. On SCS-only gateways whose firmware drops the general request *#4*0## (F450, F454, F459, H4684, MH200, MH201, MH202), each local zone asks for its own temperature with *#4*<WHERE>*0## after the startup sweep, so a standalone thermostat is not unknown until it next reports (#185). F460, F461 and MyHomeServer1 drop *#4*0## as well but answer the zone status request *#4*<WHERE>## themselves (the F460 and F461 expand it into the four dimension requests, the MyHomeServer1 replies from its cache), so their local zones keep that poll. A zone behind an F422 bus interface (WHERE = <zone>#4#<interface>) is never polled unless the OWNd profile sets supports_interface_zone_requests = True (see below), so it shows its restored reading until it reports by itself. After a restart the last reading is shown with the attribute current_temperature_restored: true until the zone reports again.
  • Current Humidity: Ambient relative humidity percentage for zones equipped with humidity sensors (e.g. Living Now thermostats or humidity probes).
  • HVAC Action and actuators: a local zone asks for the state of its actuators (*#4*<WHERE>*20##, one *#4*#0*20## for every local zone on an F461 or a MyHomeServer1) once the startup sweep is over and again after the event session reconnects, so hvac_action (heating / cooling / idle) is known right after start instead of after the first actuator switch. The attribute actuators lists each actuator as on or off ({"1": "off", "2": "off"}) and stays while the zone is off (every actuator off). F453, F453AV, H4684, MH200, MH200N and MH202 drop the request (firmware oracle), so their zones are not asked and wait for the actuators' own frames; on a shared bus the gateway that serves WHO 4 (delegated secondary or warm standby) decides. Secondary probes (WHERE >= 100) are never asked. Probe-less F430/2 / F430/4 relays (such as bathroom towel warmers that only emit Dimension 20 actuator status frames without a temperature probe) do not create phantom climate entities and can be controlled as switch entities via Add thermo actuator / towel-warmer switch (WHO 4) (see Switches & Relays).
  • Zones Behind an #4#II Interface (F422): across all twelve emulated gateway firmwares in own-firmware-oracle (findings/thermo-zone-requests.md), zero gateways emit $06EC/$06E4 interface-routed SCS telegrams for WHO = 4: gateways either NACK/drop #4#II queries, truncate Z#4#II at # and cross-poll local zone Z on the main bus (F450, F454, F459, F460, F461, H4684, MH200, MyHomeServer1), or on MH202 (1.0.24) misparse trailing #4#01 as local zone 4 actuator 1 and crash coso (SIGSEGV) on *#4*Z#4#01##. Unless an OWNd gateway profile explicitly declares supports_interface_zone_requests = True, zones configured with an #4#II interface are passive: neither polls (*#4*Z#4#II##, *0##, *11##, *19##, *20##, *60##) nor writes that would strip #4#II onto local main-bus zone Z are sent, while incoming event-session broadcasts update state normally (note that 1-digit inline shorthand 3#4#1..3#4#9 is normalized as zone 3 behind interface 01..09; wire frames always use two-digit #4#01..#4#15). Dimensionless and zone-dimension polls on actuator or split addresses (Z#N, Z#0, 0#N, 3#Z#N) are likewise never sent.

💧 Humidity Support & Startup Behavior

Climate zones equipped with integrated humidity sensors (such as BTicino Living Now or specialized probes) report relative humidity via OpenWebNet WHO = 4 Dimension 60 frames (*#4*<WHERE>*60*<HUMIDITY>##):

  • Dynamic Auto-Detection: When a climate zone emits a humidity reading on the SCS bus, the integration dynamically enables humidity tracking on that entity.
  • State Restoration Across Restarts: The zone remembers that it supports humidity across Home Assistant restarts and restores its last known humidity value immediately.
  • Targeted Startup Query: After startup (once the initial discovery sweep finishes), only climate zones that support humidity are queried with *#4*<WHERE>*60## to refresh the current reading. This avoids unnecessary bus traffic on zones without humidity sensors. A live F461 and a live MyHomeServer1 answer the request (F459 and F460 forward it in the firmware emulation); on F450, F453, F453AV, F454, H4684, MH200, MH200N and MH202 the emulated firmware did not forward it (own-firmware-oracle findings/thermo-zone-requests.md, a firmware_observed verdict), so until the OWNd gateway profile states supports_heating_humidity_request their zones are not queried. Whether those gateways put a probe's humidity on the event session has not been traced; any *#4*<WHERE>*60*<HH>## event the gateway delivers still updates current_humidity without polling.
  • Optional YAML Configuration: In advanced setups using legacy /config/myhome.yaml, humidity polling can be explicitly pre-enabled on a zone by setting humidity: true under the zone configuration.

🔄 Legacy YAML Note

Note

If you are upgrading from legacy v0.9 installations and still have manual climate: blocks in /config/myhome.yaml, please refer to the v0.9.4 Legacy Climate Documentation or the Legacy YAML Migration Guide. In v2, climate zones are auto-discovered dynamically.