Advanced Uses & Automations (v0.9.x)¶
[!NOTE] Advanced automations, OpenWebNet events, custom message sending, and hardware bus timers.
Events¶
CEN / CEN+ Scenario Pushbutton Events¶
A powerful feature is assigning CEN or CEN+ commands to physical wall switches and using the generated bus events in Home Assistant to trigger automations. CEN/CEN+ switches do not require explicit entity configuration in Home Assistant; all received messages dispatch bus events automatically.
alias: "Trigger Scene from CEN+ Wall Switch"
trigger:
- platform: event
event_type: myhome_cenplus_event
event_data:
event: pushbutton_short_press
object: 33
pushbutton: 7
action:
- action: light.toggle
target:
entity_id: light.living_room
alias: "Trigger Scene from CEN Wall Switch"
trigger:
- platform: event
event_type: myhome_cen_event
event_data:
event: pushbutton_long_release
object: 10
pushbutton: 1
action:
- action: media_player.media_play_pause
target:
entity_id: media_player.sonos_living_room
- CEN Events:
pushbutton_short_presspushbutton_short_releasepushbutton_long_presspushbutton_long_release- CEN+ Events:
pushbutton_short_presspushbutton_long_presspushbutton_long_release
Bus Broadcast Events¶
When group, area, or general commands occur on the physical bus, the integration dispatches corresponding Home Assistant events:
Light Events¶
myhome_general_light_eventmyhome_area_light_eventmyhome_group_light_event
Attributes:
- event: 'on' or 'off'
- area: Area number (for area events)
- group: Group ID (for group events, without leading #)
- message: Full raw OpenWebNet frame
Example: Synchronizing a Home Assistant Light Group with an SCS group button:
alias: "Sync MyHOME Group 1 Wall Switch"
trigger:
- platform: event
event_type: myhome_group_light_event
event_data:
group: 1
action:
- action: light.turn_{{ trigger.event.data.event }}
target:
entity_id: light.living_room_group
Automation (Cover) Events¶
myhome_general_automation_eventmyhome_area_automation_eventmyhome_group_automation_event
Attributes:
- event: 'open', 'close', or 'stop'
- area: Area number
- group: Group ID
Services¶
Instant Power Sampling (myhome.start_sending_instant_power)¶
WHO 18 power meters only report live power when explicitly polled for a set window (up to 255 minutes). You can create an automation running periodically:
Gateway Time Synchronization (myhome.sync_time)¶
Writes the Home Assistant system clock to the gateway's real-time clock:
Raw OpenWebNet Command Injection (myhome.send_message)¶
Send arbitrary OpenWebNet frames directly to the SCS bus:
⏱️ Native Bus Timers (Temporized Lights)¶
When automating lights that should turn off automatically after a set duration (corridors, staircases, pantries), software delays in Home Assistant risk leaving lights on if Home Assistant restarts.
The BTicino / Legrand MyHOME bus features actuator-level hardware timers (WHO = 1): the physical relay executes the countdown internally on the SCS bus.
1. Pre-set Timers (WHAT = 11..18)¶
WHAT Code |
Duration | Frame Syntax | Typical Application |
|---|---|---|---|
| 18 | 0.5 s | *1*18*<WHERE>## |
Door buzzer pulse, gate trigger |
| 17 | 30 s | *1*17*<WHERE>## |
Entrance courtesy light |
| 11 | 1 min | *1*11*<WHERE>## |
Pantry, walk-through hallway |
| 12 | 2 min | *1*12*<WHERE>## |
Staircase landing |
| 13 | 3 min | *1*13*<WHERE>## |
Garage entrance |
| 14 | 4 min | *1*14*<WHERE>## |
Storage room |
| 15 | 5 min | *1*15*<WHERE>## |
Garden walkway |
| 16 | 15 min | *1*16*<WHERE>## |
Utility room, carport |