Burglar Alarm (WHO = 5)¶
The MyHOME integration monitors BTicino / Legrand intrusion detection systems on OpenWebNet WHO = 5 (alarm_control_panel).
The panel is read-only: it shows the central unit's state, but it cannot arm or disarm the alarm. To arm and disarm from Home Assistant, see Arming and disarming.
In v2, setup is UI-first: the central unit is discovered from the SCS bus without manual YAML configuration files.
๐ Auto-Discovery¶
When your gateway connects to Home Assistant:
- Dynamic Bus Discovery: The first central-unit frame on the SCS bus that names the panel (for example the
*5*9*0##a disarmed panel sends when polled, or*5*8*0##when it is armed) registers thealarm_control_panelentity. - Depends on the gateway. An MH202 answers a poll with
*5*9*0##, so the panel appears at once (#564). An F454 answers with system-level frames that have an empty WHERE (*5*1*##,*5*5*##,*5*7*##,*5*9*##, see #311), and MyHOME deliberately creates no entity from an empty WHERE. On such a gateway the panel appears at the first*5*8*0##or*5*9*0##, that is the first real arm or disarm after a blank start. - Global Broadcast Zone 0 Listening: Entities follow global broadcast zone 0 telemetry (
myhome_update_<mac>_5_0) alongside their own address (myhome_update_<mac>_5_<where>), so every alarm panel stays in sync. - UI Customization: You can rename the alarm panel, assign it to an Area (e.g. Entrance, Security), and change its icon in the Home Assistant UI.
๐ก๏ธ Supported Hardware¶
The platform reads Legrand / BTicino SCS burglar alarm central units:
- BTicino 3485 / 3486: Multi-zone central alarm control units.
- BTicino HC4600 / L4600: Security control keypads and display terminals.
- BTicino 3481: Zone expansion and partition modules.
- Technical Alarm Transmitters: Flood/water leak detectors and gas safety sensors.
๐ States¶
The panel follows what the central unit reports on the bus:
| State | OpenWebNet Frame | Description |
|---|---|---|
disarmed |
*5*9*<where>##, *5*2*<where>##, *5*0*<where>## |
Disengaged, deactivated, or maintenance. |
armed_away |
*5*8*<where>## |
Engaged. |
triggered |
*5*12*, *5*15*, *5*16*, *5*17*, *5*31* |
Technical, intrusion, tampering, anti-panic or silent alarm. |
*5*1*<where>##(activation) is not an armed state. The central unit sends it while disarming (*5*2*0##โ*5*1*0##โ*5*9*0##) and in the status of a disarmed system, as well as while arming (*5*1*0##โ*5*8*0##).armed_homeis never reported: home and away arming look the same on the bus.- Zones (
*5*11*#n##active,*5*18*#n##not active) never change the panel's state.
๐ Arming and disarming¶
Current central-unit firmware rejects arm and disarm commands sent as WHO 5 frames over the SCS bus, whichever gateway sends them. A plant owner reported this, quoting BTicino support (#564), and no capture shows such a command being accepted. The alarm_control_panel entity therefore offers no arm actions, and a disarm request is refused with an error.
The route that works is an auxiliary (WHO 9) command. Your installer programs the central unit so that receiving, for example, *9*1*7## (AUX channel 7 on) arms a set of zones. Which AUX channels and values arm or disarm depends on that programming: check the central unit's configuration or ask your installer.
Combine the MyHOME panel's state with those AUX frames in a core template alarm control panel.
Warning
The template panel is a separate entity, so the MyHOME panel's refusal does not protect it. Without a code check, anyone who can reach Home Assistant can disarm the burglar alarm with one tap, including from the alarm card. The recipe below therefore asks for a code on disarm and stops unless it matches.
template:
- alarm_control_panel:
- name: Home alarm
unique_id: home_alarm
# Unavailable until the MyHOME panel has reported. Falling back to
# "disarmed" instead would show an armed alarm as disarmed after a restart.
availability: "{{ states('alarm_control_panel.alarm_0') in ['disarmed', 'armed_away', 'triggered'] }}"
state: "{{ states('alarm_control_panel.alarm_0') }}"
code_format: number
code_arm_required: false
# Example AUX frames: use the ones your central unit is programmed for
arm_away:
- action: myhome.send_message
data:
gateway: "00:03:50:00:00:00"
message: "*9*1*7##"
disarm:
# Stop here unless the right code was entered
- condition: template
value_template: "{{ code == '1234' }}"
- action: myhome.send_message
data:
gateway: "00:03:50:00:00:00"
message: "*9*0*7##"
To keep the code out of the YAML, for example if you share your configuration, move the whole template into secrets.yaml. !secret replaces a complete value, so it cannot be used inside the template string ({{ code == !secret ... }} does not work):
Alternatively, compare code against a helper, such as an input_text in password mode.
The template panel's state changes once the central unit reports *5*8*0## (armed) or *5*9*0## (disarmed) on the bus, not when the AUX frame is sent.
๐ Dashboard Display (Lovelace Alarm Panel)¶
Use the template panel on the alarm card so the buttons work:
type: alarm-panel
entity: alarm_control_panel.home_alarm
name: Home Security System
states:
- arm_away
๐งช Interactive Diagnostics via Bus Monitor¶
You can query the alarm with the Lovelace Bus Monitor Card Command Injector:
- Query Central Status:
*#5*0## - Query Zone Status:
*#5*#1##(for zone 1)
๐ Legacy YAML Note¶