Burglar Alarm (WHO = 5)

The MyHOME integration monitors BTicino / Legrand intrusion detection systems on OpenWebNet WHO = 5 (alarm_control_panel).

The panel is read-only: it shows the central unit's state, but it cannot arm or disarm the alarm. To arm and disarm from Home Assistant, see Arming and disarming.

In v2, setup is UI-first: the central unit is discovered from the SCS bus without manual YAML configuration files.


๐Ÿš€ Auto-Discovery

When your gateway connects to Home Assistant:

  1. Dynamic Bus Discovery: The first central-unit frame on the SCS bus that names the panel (for example the *5*9*0## a disarmed panel sends when polled, or *5*8*0## when it is armed) registers the alarm_control_panel entity.
  2. Depends on the gateway. An MH202 answers a poll with *5*9*0##, so the panel appears at once (#564). An F454 answers with system-level frames that have an empty WHERE (*5*1*##, *5*5*##, *5*7*##, *5*9*##, see #311), and MyHOME deliberately creates no entity from an empty WHERE. On such a gateway the panel appears at the first *5*8*0## or *5*9*0##, that is the first real arm or disarm after a blank start.
  3. Global Broadcast Zone 0 Listening: Entities follow global broadcast zone 0 telemetry (myhome_update_<mac>_5_0) alongside their own address (myhome_update_<mac>_5_<where>), so every alarm panel stays in sync.
  4. UI Customization: You can rename the alarm panel, assign it to an Area (e.g. Entrance, Security), and change its icon in the Home Assistant UI.

๐Ÿ›ก๏ธ Supported Hardware

The platform reads Legrand / BTicino SCS burglar alarm central units:

  • BTicino 3485 / 3486: Multi-zone central alarm control units.
  • BTicino HC4600 / L4600: Security control keypads and display terminals.
  • BTicino 3481: Zone expansion and partition modules.
  • Technical Alarm Transmitters: Flood/water leak detectors and gas safety sensors.

๐Ÿ”’ States

The panel follows what the central unit reports on the bus:

State OpenWebNet Frame Description
disarmed *5*9*<where>##, *5*2*<where>##, *5*0*<where>## Disengaged, deactivated, or maintenance.
armed_away *5*8*<where>## Engaged.
triggered *5*12*, *5*15*, *5*16*, *5*17*, *5*31* Technical, intrusion, tampering, anti-panic or silent alarm.
  • *5*1*<where>## (activation) is not an armed state. The central unit sends it while disarming (*5*2*0## โ†’ *5*1*0## โ†’ *5*9*0##) and in the status of a disarmed system, as well as while arming (*5*1*0## โ†’ *5*8*0##).
  • armed_home is never reported: home and away arming look the same on the bus.
  • Zones (*5*11*#n## active, *5*18*#n## not active) never change the panel's state.

๐Ÿ”‘ Arming and disarming

Current central-unit firmware rejects arm and disarm commands sent as WHO 5 frames over the SCS bus, whichever gateway sends them. A plant owner reported this, quoting BTicino support (#564), and no capture shows such a command being accepted. The alarm_control_panel entity therefore offers no arm actions, and a disarm request is refused with an error.

The route that works is an auxiliary (WHO 9) command. Your installer programs the central unit so that receiving, for example, *9*1*7## (AUX channel 7 on) arms a set of zones. Which AUX channels and values arm or disarm depends on that programming: check the central unit's configuration or ask your installer.

Combine the MyHOME panel's state with those AUX frames in a core template alarm control panel.

Warning

The template panel is a separate entity, so the MyHOME panel's refusal does not protect it. Without a code check, anyone who can reach Home Assistant can disarm the burglar alarm with one tap, including from the alarm card. The recipe below therefore asks for a code on disarm and stops unless it matches.

template:
  - alarm_control_panel:
      - name: Home alarm
        unique_id: home_alarm
        # Unavailable until the MyHOME panel has reported. Falling back to
        # "disarmed" instead would show an armed alarm as disarmed after a restart.
        availability: "{{ states('alarm_control_panel.alarm_0') in ['disarmed', 'armed_away', 'triggered'] }}"
        state: "{{ states('alarm_control_panel.alarm_0') }}"
        code_format: number
        code_arm_required: false
        # Example AUX frames: use the ones your central unit is programmed for
        arm_away:
          - action: myhome.send_message
            data:
              gateway: "00:03:50:00:00:00"
              message: "*9*1*7##"
        disarm:
          # Stop here unless the right code was entered
          - condition: template
            value_template: "{{ code == '1234' }}"
          - action: myhome.send_message
            data:
              gateway: "00:03:50:00:00:00"
              message: "*9*0*7##"

To keep the code out of the YAML, for example if you share your configuration, move the whole template into secrets.yaml. !secret replaces a complete value, so it cannot be used inside the template string ({{ code == !secret ... }} does not work):

# configuration.yaml
          - condition: template
            value_template: !secret alarm_disarm_check
# secrets.yaml
alarm_disarm_check: "{{ code == '1234' }}"

Alternatively, compare code against a helper, such as an input_text in password mode.

The template panel's state changes once the central unit reports *5*8*0## (armed) or *5*9*0## (disarmed) on the bus, not when the AUX frame is sent.


๐Ÿ“Š Dashboard Display (Lovelace Alarm Panel)

Use the template panel on the alarm card so the buttons work:

type: alarm-panel
entity: alarm_control_panel.home_alarm
name: Home Security System
states:
  - arm_away

๐Ÿงช Interactive Diagnostics via Bus Monitor

You can query the alarm with the Lovelace Bus Monitor Card Command Injector:

  • Query Central Status: *#5*0##
  • Query Zone Status: *#5*#1## (for zone 1)

๐Ÿ”„ Legacy YAML Note

Note

If you are upgrading from legacy v0.9 installations and still have manual alarm_control_panel: blocks in /config/myhome.yaml, please refer to the v0.9.4 Legacy Alarm Documentation or the Legacy YAML Migration Guide. In v2, alarm panels are discovered dynamically.